Bissell 37604 Lift-Off Pet Bagless Upright / Canister Vacuum CleanerVacuum\015 I bought belts from a vaccum repair store and was sold the wrong belts so i ordered the right belts from bissell put the belt on and in less than 5minutes the belt comes off.\015

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

If too much hair, string, or lint is caught in the brushroll, the brushroll can get stuck. If the brushroll is stuck, it will put too much strain on the belt and may cause the belt to break. Remove the brushroll and clean out any debris from the bearings. After replacing the brushroll, make sure that it turns freely.
You may have stalled the brush motor. To reset, turn off and unplug, then plug back in and turn on. The brush roll may have lodged debris or other entanglements keeping the brush from rotating. To fix, you`ll need to remove the brush roll to inspect.
If a belt is not tensioned properly, it will ride too loose or too tight on the pulley. A belt that`s too loose on a pulley will cause slippage, which leads to heat build up from friction. This heat will damage your rubber belts and cause the belts to crack and break.
The serpentine belt need constant tension on the belt to keep it from coming off. If the belt alignment is not aligned then the belt may come off. The tensioner may be out of alignment and not putting enough tension on the belt. Have a mechanic check the tensioner and replace it if needed.
Locate the brush reset button on the lower back right of the vacuum. Press the button to reset the brushroll To ensure the brush has been reset, plug the vacuum back into the electrical outlet.
Your brush will automatically shutoff if it is bound by too much hair. A blinking red light will indicate this. Turn over of the foot of the machine to expose the brush roll. Place the brush roll back into the foot, then secure it into place by locking the tab.
The BISSELL® PowerGlide® vacuum with Lift-Off® Technology offers 2 vacuums in 1 with no loss of suction* for a complete clean wherever you need it. This lightweight, bagless, upright vacuum is designed to be used on multiple surfaces, making it the perfect tool for cleaning whole rooms and even stairs.
Common causes are pulley failure, tensioner fault, failed drive belt, or a seized engine accessory. A qualified Technician such as one from YourMechanic will be able to diagnose your drive belt issues and make any repairs required to resolve the issue.
Cracks commonly begin to appear on belts that are being exposed to excessive heat. Although it cannot always be exclusively attributed to this, as pulleys and backside idlers that are too small or misaligned can also cause this cracking.
When the timing belt breaks, the crankshaft will continue to spin, while the camshaft will stop turning. As a result, the pistons will continue to rise and fall in their cylinders and can, in some instances strike the valves.
Overall, Bissell is a popular vacuum brand for a reason – these vacuums are dependable and last up to two years without issue. However, some models are better than others when it comes to cleaning different surfaces.
A possible cause might be that the tank is not properly seated. To assure the tank is seated properly, pick it up and re-seat is so it sits snugly on the unit. If this doesn`t fix the problem, make sure the tank is assembled properly. To make sure they are both latched properly, pick the tank up by its handle.
Your brush will automatically shutoff if it is bound by too much hair. A blinking red light will indicate this. Turn over of the foot of the machine to expose the brush roll. Place the brush roll back into the foot, then secure it into place by locking the tab.
Vacuum cleaners are fairly simple machines. They need power to be transmitted to the vacuum to create a suction force that lifts debris. So, the usual areas that cause suction loss include the wrong height setting, stuck rollers, a faulty gasket, a broken vacuum belt, a filled bag, or a clogged hose.
You should replace the belts on your vacuum at least every three to six months if the vacuum is regularly used. This is very important for proper cleaning.
Your brush will automatically shutoff if it is bound by too much hair. A blinking red light will indicate this. Turn over of the foot of the machine to expose the brush roll. Place the brush roll back into the foot, then secure it into place by locking the tab.
BISSELL are committed to ensuring that all products are to the highest standard. All our products have a minimum one year`s manufacturer guarantee from the date of purchase and should you experience a problem within this period please contact the BISSELL Consumer Care line on 0344 888 66 44 – Option 1.
A damaged vacuum hose, clogged motor air filter or bad suction motor can cause the vacuum cleaner to shut off during use. A tripped overload on the vacuum suction motor can shut off the vacuum cleaner during use. If your vacuum has a reset button, push it; if the vacuum seems hot, let it cool off first.
Lift-off refers to the process of exposing a pattern into photoresist (or some other material), depositing a thin film (such as a metal or dielectric) over the entire area, then washing away the photoresist (or other material) to leave behind the film only in the patterned area.
LIFTOFF:is a first-to-market effervescent energy drink tablet in the US. Is an exclusive blend of L-taurine, guarana, caffeine, Panax ginseng and Ginkgo biloba clinically proven to enhance mental performance and boost energy. Convenient, pocket-size tablet provides a mind-body boost anytime, anywhere.
Next to the motor, the belt on your vacuum is just about the most important part of your vacuum. Without the belt to spin the brushroll, most vacuums won`t pick up on carpeting at all! If your vacuum uses a rubber belt, check it once a month for cracks, melting, and especially, slippage.
Your brush will automatically shutoff if it is bound by too much hair. A blinking red light will indicate this. Turn over of the foot of the machine to expose the brush roll. Place the brush roll back into the foot, then secure it into place by locking the tab.
Your brush will automatically shutoff if it is bound by too much hair. A blinking red light will indicate this. Turn over of the foot of the machine to expose the brush roll. Place the brush roll back into the foot, then secure it into place by locking the tab.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

Windtunnel belt I have a new Hoover Windtunnel canister. The belt keeps coming off. It happened a couple weeks ago (several times after putting the belt back on) so I assumed I might need a new belt as it might have dried out at the store. I ordered new belts and today I used it for about an hour and the belt came off again, twice. There doesn’t seem to be anything to hold the belt on the stem as it seems to slip off. I have tried it centered, to the left and to the right….can you help. I am v
ANSWER : I’ve successfully used a compatible belt – Royal 104425001 .It’s still new, but for the time being at least – it works.

Is there any way to repair or replace the belt GUIDE on the inside of the belt compartment of a ’97 Hoover Wind Tunnel (not self-propelled)? It became twisted when a belt broke and now the belt rubs against it and sounds really weird, and I’m sure new belts will continue to break.. This guide is a long piece of molded material (part of the compartent wall) to keep the belt from coming off the pulley. It also had a sort of metal clip on it. It was loose and I took it off because of the way the pa
ANSWER : Honestly you should take it to a vac.shop they can fix any vac.

The original belt on my upright Kenmore Progressive broke and I replaced it with the spare that was in the vacuum. The vacuum and spare belt are about 10 years old. Then the spare broke after one vacuuming session and there was a burning smell coming from the vacuum. I ordered new belts and replaced it with the new belt. It seems to be working fine with no smell. I checked the belt after I vacuumed the family room and although it was in tact, the belt was very hot. Is that normal? Should t
ANSWER : The belt heats up due to the friction, as well as being in contact with the shaft of a hot motor. It is normal.

Hoover WindTunnel Self-Propelled V Belt
ANSWER : I had this same problem with the V belt on my Hoover Vaccuum..
.There are three (3) basic things that will cause the brush roll not to spin..
.1. When handle is upright, brush roll is OFF..2. When switch is set for HARD surface, brush roll is OFF..3. Broken/worn FLAT belt or V Belt, brush roll will not spin.
.
.I noticed that the brush roll was not spinning when my vacuum was set for CARPET. After removing the cover I noticed that the V belt was loose, I thought the belt was worn so I purchased a correct replacement belt and installed it, but the new belt was also loose and when I turned the large flat belt pulley it did not turn the V belt pulley at the same time..
.I double checked the surface setting and I had the vacuum switch set for carpet, but still when I released the handle out of the upright position the brush roll would still not spin..
.My aggravation finally led me to this posting on FixYa’s website..
.The first thing I did was checked the screw to the left of the V belt as suggested by ejmjr5 and this did nothing to solve the problem or create more tension on the V belt, even when the upright handle was not in the upright position..
.After playing around with the surface setting control switch/nob I notice that when I moved the switch out of the HARD surface setting and over to CARPET, I had thought that the switch was set for CARPET as it visually appeared, but I was not pushing the switch over hard enough to click it into the CARPET setting mode..
.VOILA, the brush roll now spins correctly even though the V belt seams to be too loose for the pulley..
.You really have to force the switch into the CARPET setting. Be sure that you hear the switch/nob click into place..
.Now you can effectively clean up after that hangover of a party!.
.Burp!

I’m using (or WAS using) a Eureka ”the boss” model 8803. The belt broke, no biggie, so I replaced it with a Eureka model U belt, the problem is when I put the new belt on and turn on the vaccuum, the belt breaks again. I am also having trouble getting the brush roller to fit right when the belt is in place. I can’t find any sharp edges that would cut the belt,nor can I find where any small bits may have broken. Anyone have a solution for me?
ANSWER : First, make sure you have the right belt, second, i am thinking that you are not lineing the roller up right, it will only fit one way. look at the ends of the roller and the grooves where it slides in, you should be able to see clearly how it goes.

Hi my proheat bissell 7901 stopped pumping water to the floor, but it pumps water from the hand hose. I read the manual and followed how to check belt and the flat belt on right side of shampooer is fine and I turned on and it turns and so do the brushes at the bottom of the machine. I was reading online and I guess there’s two belts on this machine? where can I find the other belt to see if it needs replacing. I guess it’s a ribbed belt? that is the water pump belt?
ANSWER : Just taken ours apart with the same problem… found it was caused by the 2 halves of the main casing coming apart in the area where the upright pedal release is. I found this to be due to the upper casing having broken in 2 places – the bottom of the screw wells..This means that the water tank cannot exert sufficient pressure on the valve to release the water..Only solution is a new top cover assembly

Hoover Windtunnel – the belt keeps coming off & it is the correct
ANSWER : One compatible belt that I use and works (at least while its new) is Royal 104425001. Try that.

Belt keeps coming off
ANSWER : I believe there is something wrong with the roller, could be the barrings or the end caps are warped. Try this, take the roller out and with each hand on each end hold the roller and try to spin the roller with your thumb. If it does not spin freely the problem is the roller.