Dyson DC14 Animal Bagless Upright Cyclonic Vacuum\015 Brush not rotating\015

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
Brush Head Bearings Are Clogged or Have Failed

These are symptoms of bad or dirty bearings. You should remove the brush roll or rolls from the vacuum. Check to see that the bearings at the end of the brush roll allow it to spin freely. Make sure that there is no hair trapped in the bearings.

The brush roll or its bearings may be clogged with hair, threads or dirt. Make sure they are clean and the roll spins. The belt may also have slipped because it was loose. Check the fit of the new belt when it is installed.
To reset the Brush bar press the Brush bar control button twice or switch the machine off and back on. Please note: In normal use, the Brush bar automatically turns off when the machine is upright and automatically turns on when the machine is in the vacuuming position.
The brush bar button is on the left next to the power button. The suction control slider is located on the front of the cleanerhead.
To remove, wash and replace the brush bars:

Use a coin to turn the end cap a quarter counterclockwise until it clicks into the unlocked position. Rotate the end cap to the open position. Gently slide the main brush bar out of the cleaner head.

A blockage in the machine, causing a reduction in airflow. A blockage in the head, causing it to stutter in use. An issue with the electrical pins, either in the wand or floor tool.
One of the first things to do when your Dyson vacuum cleaner keeps starting and stopping is to empty the bin. It may be full, or the machine may simply perceive it as too full to continue working. Dyson vacuum cleaners require constant airflow through them to work, and a full bin can stop this from happening.
Inspecting the Vacuum Commutator for Motor Brush Problems

Test that by turning the motor off and pushing on the center shaft, the armature. If it has any play, besides spinning, then replace the motor. If solid then replace the brushes – motor brush replacement instructions.

Press the brush control button located next to the ON/OFF switch to turn the brushbar off for vacumming delicate rugs, looped carpets and hard floors. Press the button again to restart the brushbar for vacuuming carpets.
if your dyson DC 24 has a faulty brush bar motor now sometimes the brushes on these in to suddenly stop going around the first thing to do is to look on the side the brush bar housing and click this reset switch.
If your brush is scratching your floor, or not cleaning as well as it used to, then you may want to replace your brush bar.
It turns the main brush on and off. Sorry, there was a problem.
Motorised brush bar, concentrated in a smaller head to remove stubborn dirt from mattresses, upholstery and stairs. Engineered to fit Dyson V15 Detect, Outsize™, V11™, Cyclone V10™, V8™ and V7™ vacuums.
One of the main reasons your Dyson Airwrap won`t work is because of a damaged power cable or plug. Check your power cord for any physical damage, and look for signs of wear or tear. If you notice any fraying, tears, or exposed wires, then it is likely that the cable needs to be replaced.
A blockage in the machine, causing a reduction in airflow. A blockage in the head, causing it to stutter in use. An issue with the electrical pins, either in the wand or floor tool.
It turns the main brush on and off. Sorry, there was a problem.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

My model F5906-900 — problem is the brushes have stoped working… I pulled the brush assembly out by holding the two tabs, and all seems clean and the brush assembly rotates easly… onced the brush assembly is removed. What I did notice is the female driver slot (found in the main assembly unit) that drives the brushes seems stuck..Is that normal when the machine is not hooked up to power? How can I get the brushed going??? it is a good machine, but the brush options is important too it’s ab
ANSWER : (1) Assure the Brush Control on the hood is NOT set to the OFF position.
.(2) Remove the brush assembly by pulling/unlatching it from base on each side.
.(3) Does one of the brushes have the drive pin present? It should be about ¼ inch square, and two inches long. It attaches the brushes to the drive mechanism.
.(4) Remove and clean the intake filter. One the base of the cleaner, behind the brushes, squeeze the two red abs together and pull the panel down to access the screen. Clean the hair/debris off the screen and reassemble.

Electrolux vacuum brush not turning problem:

was vacuuming and rug got caught auto shut off kicked off power to brush. instead of hitting red button to restart brush I disconnected brush to vacuum some hair in Conner. after i reconnected the brush and hit the red button but no power to brush. Light won’t even switch on. Hope you can help

ANSWER : Under the vacuum, there is a guard..remove the guard , either by 2 screws or by 2 clips..there is a belt under the guard..that is connected to the brush..the belt need to be replaced.

My hoover spin scrub brushes stopped spinning and i have cleaned intake filter and tried to turn the thing that spins it…when brushes are off the hole turns then as soon as i connect brushes the brushes will not turn what else can i do!!???
ANSWER :
This video may help you

Rotating bruch My vaccum brush will not turn. This happened after sucking up a cord that wrapped arou8nd the brush. I was able to pull the cord back out but now the brush will not turn. The vaccum does turn on an sounds like it is working with no soinning brush.
ANSWER : Take off the bottom cover where the roller brush is a few screws should be all it takes underneath cover should be roller and belt if belt is broke replace it lift up roller there is a slot for the belt to run in put other end should be the motor side put belt around pulley bar put it back the same way it came off.

hope this helps

Kenmore Canister Vac, Progressive, 25512 255513 model. Brush won’t turn. One end of the brush roller, end closest to belt, is off center which is keeping it from turning freely. The end cap is like a square. Other ends turns fine. Do these end caps come off? If so how? Can’t get it to budge. This is exactly what is keep brush roller from turning.
ANSWER : Take a flat head screw driver and pry the end cap off. It will come off. You might have some string or hair around it causing it to not turn.

Now that I just fixed my Lux Legacy canister vacuum, I need help on my other Electrolux Regency Series upright! The vacuum works fine but the rotating brush does not work and the brush motor does not turn on. Tried cleaning the brush and hitting hte reset button to no avail. This upright has a triple setting switch and I checked the each of the wires seem to be attached. Tried rotating the brush by hand and it would not budge. Was going to “encourage” the brush to turn with a set of articula
ANSWER : There are a couple rectangular holes on the bottom of the power nozzle, beside the wheels. These have tabs in them that need released with a standard screwdriver.
.rogerpotts_10.jpg.Once they release, turn the vacuum over and lift cover of power nozzle at the back. This pulls the front of the cover out of the lip on the “bumper”.
.Once this is done, you’ll need to unscrew the screw at each end of the brush. Lift the brush out and thoroughly clean it, including the ends.
. rogerpotts_9.jpg.
.Check the wiring to make sure they’re connected to the terminals of the motor. Also, check the belt for wear and tear. These belts can last for five years or more, but if it looks bad a good time to replace it is while you have the power head apart.
.When reassembling the vacuum, ensure the belt is fitted properly around the motor shaft and brush.
.Insert the front of the cover first, ensuring the edge fits neatly beneath the lip on the bumper all the way around. It takes a little manipulating to press the back into place. Make sure both tabs click into the locked position. Turn the vacuum over and reinstall screws. Try to rotate brush by hand a few times.
.At this point, plug the vacuum in and turn it on. If the power head doesn’t run, press the reset button. If the power head motor still doesn’t run, it could be due to loose or disconnected wires that lead to the reset switch, a bad reset switch, or even a bad motor. The vacuum needs to be taken to the nearest Aerus Electrolux store for further diagnosis and repair.
.
.http://www.aerushome.com/storelocator/

Roomba Discovery My Roomba turns on and moves but the brushes won’t turn. Someone told me that I had forgotten to put in the yellow and black end bearings, but I did. Help, I miss my Roomba
I have a Roomba 530, I have had it for 2 weeks and really loved it. I have followed all the cleaning instructions etc.. Then the Roomba wanted it’s brushes cleaning “please clean Roombas brushes” So thinking that something was stuck I removed and cleaned the brushes, (yellow tabs on and in place by the way)
ANSWER : I read somewhere that you need to clear the software in case there is a glitch. To do this, take the battery out and then, simultaneously hold down the “spot” and “clean” buttons for 30 seconds. Replace battery. This has worked for my Discovery model.

The brushes on the Hoover All Terrain Steamvac won’t turn. However, when I try to turn them manually they will turn. So, why won’t they turn when the machine is turned on?
ANSWER : Some vaccums have a belt on the brushes. might need a new one if it does have the belt