Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
Brush Head Bearings Are Clogged or Have Failed These are symptoms of bad or dirty bearings. You should remove the brush roll or rolls from the vacuum. Check to see that the bearings at the end of the brush roll allow it to spin freely. Make sure that there is no hair trapped in the bearings.
If your vacuum cleaner`s motor is running smoothly, but the agitator brushroll isn`t rolling as it should, you may have a faulty drive belt. Replacing a drive belt is a fairly simple task, so if you`re unsure where to start you`ve come to the right place for advice.
To reset the Brush bar press the Brush bar control button twice or switch the machine off and back on. Please note: In normal use, the Brush bar automatically turns off when the machine is upright and automatically turns on when the machine is in the vacuuming position.
A blockage in the machine, causing a reduction in airflow. A blockage in the head, causing it to stutter in use. An issue with the electrical pins, either in the wand or floor tool.
The brush bar button is on the left next to the power button. The suction control slider is located on the front of the cleanerhead.
One of the first things to do when your Dyson vacuum cleaner keeps starting and stopping is to empty the bin. It may be full, or the machine may simply perceive it as too full to continue working. Dyson vacuum cleaners require constant airflow through them to work, and a full bin can stop this from happening.
Inspecting the Vacuum Commutator for Motor Brush Problems
Test that by turning the motor off and pushing on the center shaft, the armature. If it has any play, besides spinning, then replace the motor. If solid then replace the brushes – motor brush replacement instructions.
Clear the brush roll of any hair and debris and inspect by placing it on its end and spin. The brush should spin freely. If it doesn`t spin; it may be time to replace.
If your machine has a clutch, the reason the brush bar isn`t spinning is unlikely to be a snapped belt. The clutch allows your brush roll to be turned off (for certain types of hard floors, etc.). First you should check if your brush bar is turned on. Try to turn the knob one click clockwise to the “auto” position.
If your brush is scratching your floor, or not cleaning as well as it used to, then you may want to replace your brush bar.
If you find that your machine is turning off intermittently, the filter in your vacuum is most likely full and covering the ventilation system. Remove the filter, then empty and wash it. Allow the filter to dry for at least 24 hours, or until it is completely dry.
Sometimes your vacuum pulsates on and off or keeps dying when using the extra powerful `Max Mode`, which can be related to the charge of your battery. Try turning this function off by pressing the Max button on your vacuum.
Product details
It`s recommended that you replace the HEPA Filter Cartridge Assembly on a yearly basis, as this filter can NOT be washed, and wash the secondary Pre-Motor filter once every 30 days, and replace it after 6 washing`s to maintain peak performance of your Dyson DC25.
Hold your brush bar under cold tap water and gently rub to remove any lint or dirt. Stand the brush bar upright and leave to dry completely. Make sure your brush bar is completely dry before refitting. The cleaner head housing is not washable and should only be wiped over with a damp lint-free cloth.
Reset the machine. To reset the machine, turn the power off (using either the power button on the remote or the Main body), wait 60 seconds and then turn back on.
It turns the main brush on and off.
Full-sized upright vacuum. Ball technology allows you to turn on a dime. Quick-draw telescope reach wand expands for easy high-reach cleaning. Patented Root Cyclone technology cleans all floor surfaces.
A Dyson vacuum cleaner has a lifespan of around 10 years. This is considerably longer than most other vacuums. So, if you`re looking for a high-quality vacuum cleaner that will last you for a long time, a Dyson could be a good choice. However, remember that Dyson vacuums are expensive.
Over time, all batteries are subject to degradation. So if your run time has declined when the machine is not in Max / Boost mode, it might be time to buy a new battery. All our machines come with a 2-year initial warranty that includes the battery.
Summary. Dyson batteries should last around 2-6 years before needing to be replaced. This wide range reflects the fact that how you care for and maintain the battery will affect how long it lasts. If you want your vacuum`s battery to last longer, make sure it`s stored at room temperature.
Brushes. According to iRobot, brushes should be replaced every 6-12 months. Robot vacuums like the iRobot Roomba j7+ have multiple brushes that allow it to clean.
If the roller brush is not spinning, it cannot pick up dust. One reason could be that the power button is not set to position II, which runs the roller brush. If the button does not work, here is the link to the power button replacement guide. Another reason is that the roller brush could be broken.
Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
Now that I just fixed my Lux Legacy canister vacuum, I need help on my other Electrolux Regency Series upright! The vacuum works fine but the rotating brush does not work and the brush motor does not turn on. Tried cleaning the brush and hitting hte reset button to no avail. This upright has a triple setting switch and I checked the each of the wires seem to be attached. Tried rotating the brush by hand and it would not budge. Was going to “encourage” the brush to turn with a set of articula
ANSWER : There are a couple rectangular holes on the bottom of the power nozzle, beside the wheels. These have tabs in them that need released with a standard screwdriver.
.

.Once they release, turn the vacuum over and lift cover of power nozzle at the back. This pulls the front of the cover out of the lip on the “bumper”.
.Once this is done, you’ll need to unscrew the screw at each end of the brush. Lift the brush out and thoroughly clean it, including the ends.
.

.
.Check the wiring to make sure they’re connected to the terminals of the motor. Also, check the belt for wear and tear. These belts can last for five years or more, but if it looks bad a good time to replace it is while you have the power head apart.
.When reassembling the vacuum, ensure the belt is fitted properly around the motor shaft and brush.
.Insert the front of the cover first, ensuring the edge fits neatly beneath the lip on the bumper all the way around. It takes a little manipulating to press the back into place. Make sure both tabs click into the locked position. Turn the vacuum over and reinstall screws. Try to rotate brush by hand a few times.
.At this point, plug the vacuum in and turn it on. If the power head doesn’t run, press the reset button. If the power head motor still doesn’t run, it could be due to loose or disconnected wires that lead to the reset switch, a bad reset switch, or even a bad motor. The vacuum needs to be taken to the nearest Aerus Electrolux store for further diagnosis and repair.
.
.