How to Identify and Fix Common Vacuum Problems ?
Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :
Should the brush not rotate freely there may be debris tangled around the ends of the brush, carefully remove any obstructions or replace the brush with a new one. We recommend that you fit a new belt and brush once per year to keep your Reactive vacuum working efficiently.
`Tripped` reset systems are the most common reasons for a brushbar not turning, but there are some other less common reasons too. These include: If the bearings on the end of the brushbar have seized, you won`t be able to turn it at all. This will often result in a broken belt as well, so be aware of this.
First, test the power switch for continuity to ensure that the motor is getting power. If the power switch has continuity, ensure that the blower wheel turns freely and is clear of obstructions. If power is getting to the motor, and the motor turns freely, but the motor still won`t run, replace the fan motor.
Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
You may have stalled the brush motor. To reset, turn off and unplug, then plug back in and turn on. The brush roll may have lodged debris or other entanglements keeping the brush from rotating.
Simple: the bag or canister is full and the vacuum has nowhere to store the dust it is collecting. Empty the canister or bag. If that doesn`t fix it, the vacuum filter needs to be cleaned or changed.
Clear the brush roll of any hair and debris and inspect by placing it on its end and spin. The brush should spin freely. If it doesn`t spin; it may be time to replace.
If the roller brush is not spinning, it cannot pick up dust. One reason could be that the power button is not set to position II, which runs the roller brush. If the button does not work, here is the link to the power button replacement guide. Another reason is that the roller brush could be broken.
Inspecting the Vacuum Commutator for Motor Brush Problems
Test that by turning the motor off and pushing on the center shaft, the armature. If it has any play, besides spinning, then replace the motor. If solid then replace the brushes – motor brush replacement instructions.
If you are finding that the brush head is not spinning or the light is not working, the contact patches between the main body, extension tube and the floor head may need to be cleaned. Ensure that the two connection points are clean and have no dust which could cause the connection to fail.
Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
Remove the brushroll and clean all hair, string, and lint from the brushroll bearings. If the vacuum cleaner brush still doesn`t spin after you clean the brushroll, consider replacing the brushroll.
Clear the brush roll of any hair and debris and inspect by placing it on its end and spin. The brush should spin freely. If it doesn`t spin; it may be time to replace.
If you are finding that the brush head is not spinning or the light is not working, the contact patches between the main body, extension tube and the floor head may need to be cleaned. Ensure that the two connection points are clean and have no dust which could cause the connection to fail.
Clear the brush roll of any hair and debris and inspect by placing it on its end and spin. The brush should spin freely. If it doesn`t spin; it may be time to replace.
Now that I just fixed my Lux Legacy canister vacuum, I need help on my other Electrolux Regency Series upright! The vacuum works fine but the rotating brush does not work and the brush motor does not turn on. Tried cleaning the brush and hitting hte reset button to no avail. This upright has a triple setting switch and I checked the each of the wires seem to be attached. Tried rotating the brush by hand and it would not budge. Was going to “encourage” the brush to turn with a set of articula
ANSWER : There are a couple rectangular holes on the bottom of the power nozzle, beside the wheels. These have tabs in them that need released with a standard screwdriver.
.

.Once they release, turn the vacuum over and lift cover of power nozzle at the back. This pulls the front of the cover out of the lip on the “bumper”.
.Once this is done, you’ll need to unscrew the screw at each end of the brush. Lift the brush out and thoroughly clean it, including the ends.
.

.
.Check the wiring to make sure they’re connected to the terminals of the motor. Also, check the belt for wear and tear. These belts can last for five years or more, but if it looks bad a good time to replace it is while you have the power head apart.
.When reassembling the vacuum, ensure the belt is fitted properly around the motor shaft and brush.
.Insert the front of the cover first, ensuring the edge fits neatly beneath the lip on the bumper all the way around. It takes a little manipulating to press the back into place. Make sure both tabs click into the locked position. Turn the vacuum over and reinstall screws. Try to rotate brush by hand a few times.
.At this point, plug the vacuum in and turn it on. If the power head doesn’t run, press the reset button. If the power head motor still doesn’t run, it could be due to loose or disconnected wires that lead to the reset switch, a bad reset switch, or even a bad motor. The vacuum needs to be taken to the nearest Aerus Electrolux store for further diagnosis and repair.
.
.