Kenmore Magic Blue 24195 Bagged Canister Vacuum\015 Vaccuum stopped running and I checked ba and it was full. After I changed the bag, it would not turn on.\015
How to Identify and Fix Common Vacuum Problems ?
Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :
Check service panel for tripped breakers/blown fuses. If breaker is tripped, reset it. If fuse is blown, replace it. If vacuum cleaner is plugged in, be sure power button is in the off position before resetting breaker/changing fuse.
Check that the vacuum cleaner is plugged into a working power outlet and that fuses and breakers don`t need resetting. An activated thermal cut-out due to a blockage is the next most likely cause of the problem. Check for blockages in the hose and filters, and remove any obstructions that you find.
The bottom line. Many vacuum brands recommend changing the bag before it becomes full, at least every three months.
This overload reset switch button (part number 8191505) is for vacuums. Overload reset switch button 8191505 resets the overload switch when you push it. Unplug the vacuum before installing this part. Wear work gloves to protect your hands.
Canister vacuums separate the motor and dirt container from the handle and (power) head. A hose connects the handle and head to a canister which houses the motor and dirt container. The choice of canister vs. upright vacuums depends heavily upon your usage, personal preference, and budget.
This overload reset switch button (part number 8191505) is for vacuums. Overload reset switch button 8191505 resets the overload switch when you push it. Unplug the vacuum before installing this part. Wear work gloves to protect your hands.
Check the Battery
If your robot won`t start, it likely means the battery is not holding a charge. Plug the battery into a power outlet and allow it to charge fully, and then insert it back into the vacuum and try again. Still having issues? You may need a replacement battery.
Relevant Questions and Answers :
the most relevant questions and answers related to your specific issue
I have an electrolux epic 6500 sr. The change bag light came on, I changed the bag, now it won’t run properly. If the bag is out and the hose attached it will run or if the bag is in and the hose is off it will run, but not if the bag is in and the hose is attached. Any suggestions?
ANSWER : First, if it runs without a bag, there’s a problem with the bag lock-out switch or wiring. This needs to be replaced/repaired by an authorized Aerus Electrolux technician.
.
.First, turn dial on top of vacuum counter-clockwise so the smallest dot lines up with the arrow. See if it stays on. If not, detach hose and turn vacuum on. Place palm of hand over intake. If it turns off, it’s possible that the tubes connecting to the CVA are clogged and simply need cleaned. This is most often caused by using “made to fit” Electrolux bags. Dust is sucked through the bags and into the motor compartment of the machine. All interior parts get covered in dust and need to be cleaned. If this is the cause, the vacuum is best cleaned and repaired at an authorized Aerus Electrolux store. If the vacuum shuts off, or won’t turn on before placing hand over the intake, it’s probable the control valve assembly is bad and needs replaced.
Another cause is an overheated motor due to clogged screen at back of bag well, full or clogged bag, dirty afterfilter, bad wiring/connections, clogged hose, clogged power head, or bad motor. It depends largely on the type and model of cleaner. Clogged wands are also a possibility, but unlikely.
Check and clean screen at back of bag well.
Replace bag. Make sure it’s a genuine Electrolux bag made by Home Solutions.
Check and replace afterfilter if necessary. These should be replaced after every six bags.
Broken and worn wiring connections are often found in the hose ends due to abuse and normal wear and tear. You can check the continuity of the hose using a continuity tester or multi-tester. If a multi-tester, turn dial to one of the Ohm settings. Place one probe into one of the terminals on the end of the hose. This will be referred to as T1. Touch the other probe to each of the terminals/connections on the other end of the hose. These will be T3 and T4. One of them should read zero, the other should read infinity. Repeat this with the other terminal, which will be T2.
Drop a marble in one end of hose and let it roll through. If it doesn’t roll through, the hose is clogged and needs to be cleared. Plug hose into the exhaust port of the vacuum, place other end in the in port. Turn vacuum on. This provides a blowing and sucking action which should clear the hose.
Detach hose from power nozzle (PN). Drop a marble into the wand end of PN. If it rolls through, it’s clear. If not, there’s probably a clog behind the brush where the intake opening is. You may be able to reach this through wand end with needle nose pliers, or either end with a knitting/crochet needle or a bent coat hanger.
If none of these “fixes” provide the answer to the problem, it should be taken to the nearest Aerus Electrolux store for diagnosis. Repairs or checks involving disassembly of the vacuum should always be done by an authorized Aerus Electrolux service technician.
The store nearest you can be found by following the instructions at the below listed link:
http://www.aerushome.com/storelocator/
Electrolux Epic 6500SR Full Bag sensor working, Does not Reset properly
ANSWER : The problem was a sticking switch that was not being reset. The vacuum on/off switch mechanism is comprised of two switches. One is the main switch that turns the vacuum on and off. The second is a shut off switch that gets tripped when the full bag sensor is engaged. This second switch is supposed to get reset when you push the on/off switch on the outside of the machine. The full bag shutoff switch was stiff and it, therefore, was taking a couple of presses of the on/off switch to move the shutoff switch back into the running position.
Bag full indication comes on; changed bag; still wont run.
ANSWER : Turn the knob on the top of the vacuum all the way to the right and try it again
My electrolux oxygen cannister has the “bag change” light on when there is a new bag. The light stays on when the suction power is high (to pick up small particles) and it won’t pick up, but the ight goes off when the suction power is low (to pick up big objects). I changed the hepa filter, cleaned the motor filter and changed bags, but all that didn’t help.
ANSWER : You may have a clog in the hose, and/or the inlet by the brush roll. A clog will turn on that light as well as a full bag.
On my M&S Air Vac AV425 central vaccuum system, the system usually turns on by inserting the vaccuum hose into one of the vaccuum outlets. However, it now runs continuously. I am able to turn it off only by unplugging the vaccuum from the electrical outlet. I would like to know how to trouble shoot the problem or how to find someone who services Air Vac systems in the Bridgewater, New jersey area.
ANSWER : We are a central vacuum service company and we service all of new jersey. sounds like you have a short some where that keeps your unit running or it could be your relay module thats stuck our number is 908-721-7595 its j&j central vacuum services
I recently put a call into dyson regarding a problem with my vaccuum and a supervisor was supposed to get back to me. no one has. back in august, we were on the phone with a technician regarding a problem with out machine. after trying a list of things, she said to take it to american vaccuum services and it would be covered by dyson. when i did, the man told me it was clogged and i would owe $45. i would not have taken it for that price! please advise as now i am stuck. i want my vaccuum and th
ANSWER : Unless you can Dyson to intervene and have this repair covered under their warranty, You are stuck to pay for the service. Clogs may not be covered under warranty, but I don’t know how their warranty states. If it says that if you have a problem, take it in for repair, and it will be repaired to the orginal state, then a clog should be covered. But some shops will charge an adminstration type fee even if it is under warranty as the warranty doesn’t pay hardly anything.
Miele Mistral S7280 won’t run after changing the bag
ANSWER : The Mistral range is the same as the new S7 that’s just hit Europe. Have you made sure that when you turn on the vac on the handle that you’ve switched the carpet mode on? There’s a separate button just under the power on button that activates the Carpet setting. Other than that check the sole plate where the roller brush to check for a blockage.
Bag was full, changed it, the unit now turns off
ANSWER : Try dialing the control valve to the mid way position. If the unit still shuts down with the bag full light on you have a damaged control valve under the dial on the top of the vac.
This valve failure is common in this model and can only be repaired by someone with original AERUS Electrolux repair parts, generally at an AERUS repair shop.