Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
These are symptoms of bad or dirty bearings. You should remove the brush roll or rolls from the vacuum. Check to see that the bearings at the end of the brush roll allow it to spin freely. Make sure that there is no hair trapped in the bearings.
Relevant Questions and Answers :
the most relevant questions and answers related to your specific issue
You can check the latter simply by removing the sole plate and looking. Unfortunately the other belt is hidden under a plastic cover, so you cant see if it is okay or not without some dismantling. This cover is not easy to remove and requires a Torx driver to under the securing screws.
If, after removing the cover, the other belt is okay, then you have a faulty clutch. New clutches are available on eBay reasonably cheaply, but again good tools and DIY skills are required.
Have a look atwww.dysonmedic.com which has some excellent info on dismantling and repairing a DC 07, but unless you have access to such tools, and feel confident to tackle it, it’s probably time to callDyson or a Vacuum repairer.
*An example of a brush roll*
Make sure that the brush roll spins freely.
Hope that helps.
Chris
.a) The selector on the front of your machine is set to hard floors
.b) The bearings in your brush roller are jammed
.c) the clutch to motor belt (this vacuum has 2 belts) is broken.
.I have made a youtube video of how to check the clutch and brush.
.If you need parts or filters you an go to vacuumspot.com.au or nelsonvacuums.com.au
.Hope this helps 🙂
.oh also if this is helpful please take the time to write a review or give me a thumbs up
.
.

.Once this is done, you’ll need to unscrew the screw at each end of the brush. Lift the brush out and thoroughly clean it, including the ends.
.

.Check the wiring to make sure they’re connected to the terminals of the motor. Also, check the belt for wear and tear. These belts can last for five years or more, but if it looks bad a good time to replace it is while you have the power head apart.
.When reassembling the vacuum, ensure the belt is fitted properly around the motor shaft and brush.
.Insert the front of the cover first, ensuring the edge fits neatly beneath the lip on the bumper all the way around. It takes a little manipulating to press the back into place. Make sure both tabs click into the locked position. Turn the vacuum over and reinstall screws. Try to rotate brush by hand a few times.
.At this point, plug the vacuum in and turn it on. If the power head doesn’t run, press the reset button. If the power head motor still doesn’t run, it could be due to loose or disconnected wires that lead to the reset switch, a bad reset switch, or even a bad motor. The vacuum needs to be taken to the nearest Aerus Electrolux store for further diagnosis and repair.
.
.http://www.aerushome.com/storelocator/
.There are three (3) basic things that will cause the brush roll not to spin..
.1. When handle is upright, brush roll is OFF..2. When switch is set for HARD surface, brush roll is OFF..3. Broken/worn FLAT belt or V Belt, brush roll will not spin.
.
.I noticed that the brush roll was not spinning when my vacuum was set for CARPET. After removing the cover I noticed that the V belt was loose, I thought the belt was worn so I purchased a correct replacement belt and installed it, but the new belt was also loose and when I turned the large flat belt pulley it did not turn the V belt pulley at the same time..
.I double checked the surface setting and I had the vacuum switch set for carpet, but still when I released the handle out of the upright position the brush roll would still not spin..
.My aggravation finally led me to this posting on FixYa’s website..
.The first thing I did was checked the screw to the left of the V belt as suggested by ejmjr5 and this did nothing to solve the problem or create more tension on the V belt, even when the upright handle was not in the upright position..
.After playing around with the surface setting control switch/nob I notice that when I moved the switch out of the HARD surface setting and over to CARPET, I had thought that the switch was set for CARPET as it visually appeared, but I was not pushing the switch over hard enough to click it into the CARPET setting mode..
.VOILA, the brush roll now spins correctly even though the V belt seams to be too loose for the pulley..
.You really have to force the switch into the CARPET setting. Be sure that you hear the switch/nob click into place..
.Now you can effectively clean up after that hangover of a party!.
.Burp!