Dyson DC25 All Floors Bagless Upright Vacuum

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

If your vacuum`s brush bar is not turning, the bar may be clogged from hair and other debris. Ensure that the brushbar button, which is gray and located next to the power button, is turned on. If this is not the issue, then the brushbar itself may be damaged or stuck.
Answer:The breaker switch pops out when triggered and is pushed back in to be reset.
To reset the Brush bar press the Brush bar control button twice or switch the machine off and back on. Please note: In normal use, the Brush bar automatically turns off when the machine is upright and automatically turns on when the machine is in the vacuuming position.
Press the brush control button located next to the ON/OFF switch to turn the brushbar off for vacumming delicate rugs, looped carpets and hard floors. Press the button again to restart the brushbar for vacuuming carpets.
If your dyson vacuum isn`t turning on, don`t panic – there are a couple possible causes. It could simply be that the vacuum overheated and shut itself off. If that is the case, wait 24 hours and turn it back on. However, another problem with dysons are failed power switches.
Reset the machine without the app

The machine allows you to clear your WiFi settings, restoring the machine to the factory default. Press and hold the `Standby ON/OFF` button on the purifier for longer than 20 seconds.

A Dyson vacuum cleaner has a lifespan of around 10 years. This is considerably longer than most other vacuums. So, if you`re looking for a high-quality vacuum cleaner that will last you for a long time, a Dyson could be a good choice. However, remember that Dyson vacuums are expensive.
If you have ruled out an electrical problem in your house then firstly check your Dyson`s fuse, only replace it with a 13A fuse which is usually brown in colour. If you replace it with a smaller fuse it will blow that fuse immediately and lead you down the garden path to a problem that may not exist.
Dyson invested £2.5 billion in research and development.

While you might feel that this is the reason their products are expensive, you`re highly mistaken. This investment was mainly to accommodate a centre for their 1,200 employees, 22 laboratories, prototyping space, and areas for collaborative work.

When MAX mode is selected, the MAX button will light up. You`ll also hear the motor change pitch as the speed of the impeller increases. To change back to regular high power suction, just press and release the MAX button again.
If your brush is scratching your floor, or not cleaning as well as it used to, then you may want to replace your brush bar.
In many cases, you probably can repair a Dyson yourself, especially when it comes to common issues (see below). However, even if your machine needs some extra TLC by a Dyson expert, it can be worth getting it repaired.
If all you hear from the vacuum unit is a click at the when you try to start the vacuum motor from inside the house, then the motor in the unit is dead and has to be replaced. A strong odor from the shellac, which coats the copper coil windings, is an indicator that the motor is about to or has burnt out.
Check for a plugged hose:

Plugged vacuum hoses are sometimes the reason for a loss in suction. Hoses can get clogged with hair, dust bunnies, string, or anything else that can`t pass through the other end of the hose. Airways inside the machine should be looked at as well. Wherever there is an air passage, check it.

Clear the brush roll of any hair and debris and inspect by placing it on its end and spin. The brush should spin freely. If it doesn`t spin; it may be time to replace.
If you checked your brush roll, floor setting, and belt but your brush roll is still not spinning, that means you probably need a Shark micro switch replacement. This small switch tells the vacuums brush when to start spinning.
If your Dyson vacuum`s suction motor isn`t working, first check that the machine receives power from the wall socket or its battery pack. If the motor still doesn`t work, it`s likely an airflow problem. Blockages will cause the vacuum to overheat, so the suction motor stops or pulsates to protect itself from damage.
One of the first things to do when your Dyson vacuum cleaner keeps starting and stopping is to empty the bin. It may be full, or the machine may simply perceive it as too full to continue working. Dyson vacuum cleaners require constant airflow through them to work, and a full bin can stop this from happening.
If your Dyson vacuum`s suction motor isn`t working, first check that the machine receives power from the wall socket or its battery pack. If the motor still doesn`t work, it`s likely an airflow problem. Blockages will cause the vacuum to overheat, so the suction motor stops or pulsates to protect itself from damage.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

Electrolux vacuum brush not turning problem:

was vacuuming and rug got caught auto shut off kicked off power to brush. instead of hitting red button to restart brush I disconnected brush to vacuum some hair in Conner. after i reconnected the brush and hit the red button but no power to brush. Light won’t even switch on. Hope you can help

ANSWER : Under the vacuum, there is a guard..remove the guard , either by 2 screws or by 2 clips..there is a belt under the guard..that is connected to the brush..the belt need to be replaced.

Dyson dc25 off button won’t turn off, brush button won’t engage brushes
ANSWER : Hi … did u get this fixed cos mine is the same hve to switch off on the wall?

Now that I just fixed my Lux Legacy canister vacuum, I need help on my other Electrolux Regency Series upright! The vacuum works fine but the rotating brush does not work and the brush motor does not turn on. Tried cleaning the brush and hitting hte reset button to no avail. This upright has a triple setting switch and I checked the each of the wires seem to be attached. Tried rotating the brush by hand and it would not budge. Was going to “encourage” the brush to turn with a set of articula
ANSWER : There are a couple rectangular holes on the bottom of the power nozzle, beside the wheels. These have tabs in them that need released with a standard screwdriver.
.rogerpotts_10.jpg.Once they release, turn the vacuum over and lift cover of power nozzle at the back. This pulls the front of the cover out of the lip on the “bumper”.
.Once this is done, you’ll need to unscrew the screw at each end of the brush. Lift the brush out and thoroughly clean it, including the ends.
. rogerpotts_9.jpg.
.Check the wiring to make sure they’re connected to the terminals of the motor. Also, check the belt for wear and tear. These belts can last for five years or more, but if it looks bad a good time to replace it is while you have the power head apart.
.When reassembling the vacuum, ensure the belt is fitted properly around the motor shaft and brush.
.Insert the front of the cover first, ensuring the edge fits neatly beneath the lip on the bumper all the way around. It takes a little manipulating to press the back into place. Make sure both tabs click into the locked position. Turn the vacuum over and reinstall screws. Try to rotate brush by hand a few times.
.At this point, plug the vacuum in and turn it on. If the power head doesn’t run, press the reset button. If the power head motor still doesn’t run, it could be due to loose or disconnected wires that lead to the reset switch, a bad reset switch, or even a bad motor. The vacuum needs to be taken to the nearest Aerus Electrolux store for further diagnosis and repair.
.
.http://www.aerushome.com/storelocator/

Kenmore Canister Vac, Progressive, 25512 255513 model. Brush won’t turn. One end of the brush roller, end closest to belt, is off center which is keeping it from turning freely. The end cap is like a square. Other ends turns fine. Do these end caps come off? If so how? Can’t get it to budge. This is exactly what is keep brush roller from turning.
ANSWER : Take a flat head screw driver and pry the end cap off. It will come off. You might have some string or hair around it causing it to not turn.

The brushes on the Hoover All Terrain Steamvac won’t turn. However, when I try to turn them manually they will turn. So, why won’t they turn when the machine is turned on?
ANSWER : Some vaccums have a belt on the brushes. might need a new one if it does have the belt

Rotating bruch My vaccum brush will not turn. This happened after sucking up a cord that wrapped arou8nd the brush. I was able to pull the cord back out but now the brush will not turn. The vaccum does turn on an sounds like it is working with no soinning brush.
ANSWER : Take off the bottom cover where the roller brush is a few screws should be all it takes underneath cover should be roller and belt if belt is broke replace it lift up roller there is a slot for the belt to run in put other end should be the motor side put belt around pulley bar put it back the same way it came off.

hope this helps

The beater bar on my Dyson won’t turn. The vacuum runs and suctions but the bar won’t turn and the belt is not broke. The beater bar did get a carpet fiber caught and wrapped around it which stopped the bar and I removed the bar to cut the fiber loose and replaced it and now it won’t turn
ANSWER : The belt doesn’t have to be broken to make the vacuum not work correctly. If the belt is stretched the vacuum won’t operate the way it is supposed to. You can get replacement Dyson Belts here:

Dyson Replacement Belts

Roomba Discovery My Roomba turns on and moves but the brushes won’t turn. Someone told me that I had forgotten to put in the yellow and black end bearings, but I did. Help, I miss my Roomba
I have a Roomba 530, I have had it for 2 weeks and really loved it. I have followed all the cleaning instructions etc.. Then the Roomba wanted it’s brushes cleaning “please clean Roombas brushes” So thinking that something was stuck I removed and cleaned the brushes, (yellow tabs on and in place by the way)
ANSWER : I read somewhere that you need to clear the software in case there is a glitch. To do this, take the battery out and then, simultaneously hold down the “spot” and “clean” buttons for 30 seconds. Replace battery. This has worked for my Discovery model.