Electrolux Eureka Boss SmartVac Vacuum Cleaner 4870PZ
How to Identify and Fix Common Vacuum Problems ?
Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :
This is due to the city`s proximity to large agricultural areas and its relatively inexpensive housing. The city`s median home price is $362,600, which is way lesser than California`s median home price of $600,000.
Relevant Questions and Answers :
the most relevant questions and answers related to your specific issue
I just changed the bag and filters. The machine runs, seems normal, but there is no suction. There is no blockage of the hose, as indicated by the fact that that little viewer window above where the hose connects to the unit is not showing the red portion that it shows when there is something blocking the hose (god, this is hard to describe!).
If I disconnect the hose and put my hand over the hole, I feel some suction. But
.
.First, turn dial on top of vacuum counter-clockwise so the smallest dot lines up with the arrow. See if it stays on. If not, detach hose and turn vacuum on. Place palm of hand over intake. If it turns off, it’s possible that the tubes connecting to the CVA are clogged and simply need cleaned. This is most often caused by using “made to fit” Electrolux bags. Dust is sucked through the bags and into the motor compartment of the machine. All interior parts get covered in dust and need to be cleaned. If this is the cause, the vacuum is best cleaned and repaired at an authorized Aerus Electrolux store. If the vacuum shuts off, or won’t turn on before placing hand over the intake, it’s probable the control valve assembly is bad and needs replaced.
Another cause is an overheated motor due to clogged screen at back of bag well, full or clogged bag, dirty afterfilter, bad wiring/connections, clogged hose, clogged power head, or bad motor. It depends largely on the type and model of cleaner. Clogged wands are also a possibility, but unlikely.
Check and clean screen at back of bag well.
Replace bag. Make sure it’s a genuine Electrolux bag made by Home Solutions.
Check and replace afterfilter if necessary. These should be replaced after every six bags.
Broken and worn wiring connections are often found in the hose ends due to abuse and normal wear and tear. You can check the continuity of the hose using a continuity tester or multi-tester. If a multi-tester, turn dial to one of the Ohm settings. Place one probe into one of the terminals on the end of the hose. This will be referred to as T1. Touch the other probe to each of the terminals/connections on the other end of the hose. These will be T3 and T4. One of them should read zero, the other should read infinity. Repeat this with the other terminal, which will be T2.
Drop a marble in one end of hose and let it roll through. If it doesn’t roll through, the hose is clogged and needs to be cleared. Plug hose into the exhaust port of the vacuum, place other end in the in port. Turn vacuum on. This provides a blowing and sucking action which should clear the hose.
Detach hose from power nozzle (PN). Drop a marble into the wand end of PN. If it rolls through, it’s clear. If not, there’s probably a clog behind the brush where the intake opening is. You may be able to reach this through wand end with needle nose pliers, or either end with a knitting/crochet needle or a bent coat hanger.
If none of these “fixes” provide the answer to the problem, it should be taken to the nearest Aerus Electrolux store for diagnosis. Repairs or checks involving disassembly of the vacuum should always be done by an authorized Aerus Electrolux service technician.
The store nearest you can be found by following the instructions at the below listed link:
http://www.aerushome.com/storelocator/
Here is a tip that will give you all the information you need to fix your BissellProheat Vacuum Problem.
Bissell Proheat Upright Wet/Dry Vacuum Problems
heatman101 .
.xbnxb
.Tear in Eureka Upright “The Boss” 4870
.Posted by kdunnett on Jun 07, 2008
.I have a tear in the hose of an upright Eureka “The Boss” 4870 vacuum. I cannot find how to release the parts I need to get the hose out and put in a new hose (which I already have) I’ve searched the Eureka site and the owner’s manual – nothing about how to replace the hose itself. Thanks in advance.
.
.Hello,
I would advise you to ALWAYS to FIRST UNPLUG YOUR VACUUM before beginning any service procedure. Eureka 431A Optima Bagless Upright Vacuum. In answer to your question, the owner’s manual may or may not give an example to install the hose only, but on most vacuums the hose sometimes will screw in to the hose cuff on both ends unless if it is a hose assm then it will then twist and turn. Check with the Eureka website and have them send out a schematic and owner’s manual for you so that you can install your hose properly. Sometimes you have to place hose glue on the end of each side in order for the hose to screw in properly. the website address will be listed below and they certainly should supply you with the owners’ manual and maybe a schematic of the parts breakdown that also may help. If not; check with your local vacuum cleaner dealer in your area. So if you need further assistance, please feel free to contact your local vacuum cleaner dealer in your area or in the yellow pages, or contact the factory phone number or website to further assist you with your questions.
.http://www.eureka.com Customer Service 1-800-282-2886
.Customer Service Dept for U.S.
.Electrolux Home Care Products
.P.O. Box 3900
.Peoria. IL 61612
.
..
Hours of Operation
.Monday thru Friday 8:00am to 7:30pm CST
.Saturday and Sunday 10:00am to 6:30pm CST
.Thanks, Don the Vac Man
Go Ahead. Use Us.
the wand or hose with a heatgun or torch
to flex it and then try plugging it in.