Dyson DC14 Animal Bagless Upright Cyclonic Vacuum\015 Well….how do you do it…sometime soon\015

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

If your LED flickers a lot like on the third animation you MUST change your belt immediately. If you can barely see the green LED or is permanently off change your belt immediately and book your machine for service.
If too much hair, string, or lint is caught in the brushroll, the brushroll can get stuck. If the brushroll is stuck, it will put too much strain on the belt and may cause the belt to break. Remove the brushroll and clean out any debris from the bearings. After replacing the brushroll, make sure that it turns freely.
The DC14 was released in 2004. It is a revision of the DC07 upright vacuum cleaner with lower centre of gravity and `telescope reach`. It uses Dyson`s Root 8 Cyclone technology, which maintains constant suction.
Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
Most cases of a jammed or stuck brush bar are quick and easy to fix, simply pulling the debris gently from the brush bar. Alternatively, if you need to clear a problematic blockage, you can take the brush bar out of the housing easily, for quick maintenance.
Dyson Belts, Fits: All Upright Vacuum Cleaner Models Using one Belt System, 3 Belts in Pack.
Dyson DC14 models come in two variants; with and without a clutch. For those without a clutch, a single drive belt connects the motor directly to the brush so the brush rotates continuously whenever the motor is on.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

The original belt on my upright Kenmore Progressive broke and I replaced it with the spare that was in the vacuum. The vacuum and spare belt are about 10 years old. Then the spare broke after one vacuuming session and there was a burning smell coming from the vacuum. I ordered new belts and replaced it with the new belt. It seems to be working fine with no smell. I checked the belt after I vacuumed the family room and although it was in tact, the belt was very hot. Is that normal? Should t
ANSWER : The belt heats up due to the friction, as well as being in contact with the shaft of a hot motor. It is normal.

Belt replacement i am trying to replace the belt on my kirby g4 and i can not get the rooler off to replace the belt. if you could tell me how to do this it would be great.
ANSWER : Lift the light bulb housing up and you will find a latch that will rotate to release the front agitator housing and remove it from the machine. On the bottom of that housing, there are two latches that secure the bottom plate that covers the roller. Remove the plate and the roller will come out. Be sure to notice that the roller has a magnet at one end that lines up with the indicator that shows you when the roller is turning – it’s the little green light that glows while you are vacuuming. The roller needs to go back in the same way it came out. O.K. Take your new belt and position it around the middle of the roller and drop the roller back into place and replace the bottom plate. On the front of the housing, there is a big square “knob” and you can rotate that piece. If you look inside the hole on the other side of the agitator housing, you will see that there is an arm that moves with the square knob. The end of this arm will catch the belt and with a little effort, the knob will rotate and lift the belt into position for replacing the housing back on to the machine. once you have the housing back on the machine and secure, you rotate the square knob back around and the belt will sit down on the drive shaft. If you look at the top of the agitator housing just above where the knob is, you will see a red and a green arrow which indicate which way the knob turns to do the “remove” belt or “replace” belt. I hope this helps. Once you do it properly, it actually is quite easy.
.Rating

Hoover WindTunnel Self-Propelled V Belt
ANSWER : I had this same problem with the V belt on my Hoover Vaccuum..
.There are three (3) basic things that will cause the brush roll not to spin..
.1. When handle is upright, brush roll is OFF..2. When switch is set for HARD surface, brush roll is OFF..3. Broken/worn FLAT belt or V Belt, brush roll will not spin.
.
.I noticed that the brush roll was not spinning when my vacuum was set for CARPET. After removing the cover I noticed that the V belt was loose, I thought the belt was worn so I purchased a correct replacement belt and installed it, but the new belt was also loose and when I turned the large flat belt pulley it did not turn the V belt pulley at the same time..
.I double checked the surface setting and I had the vacuum switch set for carpet, but still when I released the handle out of the upright position the brush roll would still not spin..
.My aggravation finally led me to this posting on FixYa’s website..
.The first thing I did was checked the screw to the left of the V belt as suggested by ejmjr5 and this did nothing to solve the problem or create more tension on the V belt, even when the upright handle was not in the upright position..
.After playing around with the surface setting control switch/nob I notice that when I moved the switch out of the HARD surface setting and over to CARPET, I had thought that the switch was set for CARPET as it visually appeared, but I was not pushing the switch over hard enough to click it into the CARPET setting mode..
.VOILA, the brush roll now spins correctly even though the V belt seams to be too loose for the pulley..
.You really have to force the switch into the CARPET setting. Be sure that you hear the switch/nob click into place..
.Now you can effectively clean up after that hangover of a party!.
.Burp!

The belt on my Kirby G3 wore out, and I bought replacement belts from two different sources–one an official Kirby supplier and one a store brand. Neither belt is long enough to catch the belt lifter when it is rotated and to reach the drive shaft.
ANSWER : Kirby has only had 1 belt from day one. sometimes you do need to push the belt up to catch the belt lifter

Hi my proheat bissell 7901 stopped pumping water to the floor, but it pumps water from the hand hose. I read the manual and followed how to check belt and the flat belt on right side of shampooer is fine and I turned on and it turns and so do the brushes at the bottom of the machine. I was reading online and I guess there’s two belts on this machine? where can I find the other belt to see if it needs replacing. I guess it’s a ribbed belt? that is the water pump belt?
ANSWER : Just taken ours apart with the same problem… found it was caused by the 2 halves of the main casing coming apart in the area where the upright pedal release is. I found this to be due to the upper casing having broken in 2 places – the bottom of the screw wells..This means that the water tank cannot exert sufficient pressure on the valve to release the water..Only solution is a new top cover assembly

Is there any way to repair or replace the belt GUIDE on the inside of the belt compartment of a ’97 Hoover Wind Tunnel (not self-propelled)? It became twisted when a belt broke and now the belt rubs against it and sounds really weird, and I’m sure new belts will continue to break.. This guide is a long piece of molded material (part of the compartent wall) to keep the belt from coming off the pulley. It also had a sort of metal clip on it. It was loose and I took it off because of the way the pa
ANSWER : Honestly you should take it to a vac.shop they can fix any vac.

Windtunnel belt I have a new Hoover Windtunnel canister. The belt keeps coming off. It happened a couple weeks ago (several times after putting the belt back on) so I assumed I might need a new belt as it might have dried out at the store. I ordered new belts and today I used it for about an hour and the belt came off again, twice. There doesn’t seem to be anything to hold the belt on the stem as it seems to slip off. I have tried it centered, to the left and to the right….can you help. I am v
ANSWER : I’ve successfully used a compatible belt – Royal 104425001 .It’s still new, but for the time being at least – it works.

I’m using (or WAS using) a Eureka ”the boss” model 8803. The belt broke, no biggie, so I replaced it with a Eureka model U belt, the problem is when I put the new belt on and turn on the vaccuum, the belt breaks again. I am also having trouble getting the brush roller to fit right when the belt is in place. I can’t find any sharp edges that would cut the belt,nor can I find where any small bits may have broken. Anyone have a solution for me?
ANSWER : First, make sure you have the right belt, second, i am thinking that you are not lineing the roller up right, it will only fit one way. look at the ends of the roller and the grooves where it slides in, you should be able to see clearly how it goes.