ecked that all hose is clear.
If I leave the vacum on low intensity the suction is minimal and does not increas when I turn up the suction.
Is there a solution to this?
I look forward to your response
Dirt Devil M084105 Jaguar Vacuum

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

Check the power unit reset button located above the power cord. Pressing the button should restore operation. NOTE: The reset button is located on the upper left-hand side of the unit where the low voltage wires connect to the unit.
Airflow Issues

If the device is clogged, or the dirt cup is full, this may cause the unit to overheat. Unplug the unit and allow it cool, empty the dirt cup and clean the filter.

If your vacuum cleaner keeps turning off, this could be due to the following reasons: Blockages – check the hose and head for any obstructions. Filter – always check your filters, if these are clogged this could be causing the vacuum cleaner to work harder and lose suction power.
A damaged vacuum hose, clogged motor air filter or bad suction motor can cause the vacuum cleaner to shut off during use. A tripped overload on the vacuum suction motor can shut off the vacuum cleaner during use. If your vacuum has a reset button, push it; if the vacuum seems hot, let it cool off first.
One of the easiest ways to increase vacuum cleaner suction is to empty the dust bag or container. Dust containers need to have enough space for airflow, otherwise, they could get clogged and have less suction power. Regularly check your dust compartment and empty or change it when it`s already 70-80% full.
Check that the vacuum cleaner is plugged into a working power outlet and that fuses and breakers don`t need resetting. An activated thermal cut-out due to a blockage is the next most likely cause of the problem. Check for blockages in the hose and filters, and remove any obstructions that you find.
Remove the brushroll and clean all hair, string, and lint from the brushroll bearings. If the vacuum cleaner brush still doesn`t spin after you clean the brushroll, consider replacing the brushroll.
Check that the vacuum cleaner is plugged into a working power outlet and that fuses and breakers don`t need resetting. An activated thermal cut-out due to a blockage is the next most likely cause of the problem. Check for blockages in the hose and filters, and remove any obstructions that you find.
The exhaust filter traps particles as the air travels through the vacuum cleaner. If the filter is clogged, the vacuum cleaner will not have proper suction. If your vacuum filter is clogged, refer to your owner`s manual for cleaning instructions.
The most common cause of vacuum cleaner not picking up dirt properly is clogged air filter. Remove the filter and either clean or replace it as needed.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

Electrolux Epic 6500SR Full Bag sensor working, Does not Reset properly
ANSWER : The problem was a sticking switch that was not being reset. The vacuum on/off switch mechanism is comprised of two switches. One is the main switch that turns the vacuum on and off. The second is a shut off switch that gets tripped when the full bag sensor is engaged. This second switch is supposed to get reset when you push the on/off switch on the outside of the machine. The full bag shutoff switch was stiff and it, therefore, was taking a couple of presses of the on/off switch to move the shutoff switch back into the running position.

I have an electrolux epic 6500 sr. The change bag light came on, I changed the bag, now it won’t run properly. If the bag is out and the hose attached it will run or if the bag is in and the hose is off it will run, but not if the bag is in and the hose is attached. Any suggestions?
ANSWER : First, if it runs without a bag, there’s a problem with the bag lock-out switch or wiring. This needs to be replaced/repaired by an authorized Aerus Electrolux technician.
.
.First, turn dial on top of vacuum counter-clockwise so the smallest dot lines up with the arrow. See if it stays on. If not, detach hose and turn vacuum on. Place palm of hand over intake. If it turns off, it’s possible that the tubes connecting to the CVA are clogged and simply need cleaned. This is most often caused by using “made to fit” Electrolux bags. Dust is sucked through the bags and into the motor compartment of the machine. All interior parts get covered in dust and need to be cleaned. If this is the cause, the vacuum is best cleaned and repaired at an authorized Aerus Electrolux store. If the vacuum shuts off, or won’t turn on before placing hand over the intake, it’s probable the control valve assembly is bad and needs replaced.

Another cause is an overheated motor due to clogged screen at back of bag well, full or clogged bag, dirty afterfilter, bad wiring/connections, clogged hose, clogged power head, or bad motor. It depends largely on the type and model of cleaner. Clogged wands are also a possibility, but unlikely.

Check and clean screen at back of bag well.

Replace bag. Make sure it’s a genuine Electrolux bag made by Home Solutions.

Check and replace afterfilter if necessary. These should be replaced after every six bags.

Broken and worn wiring connections are often found in the hose ends due to abuse and normal wear and tear. You can check the continuity of the hose using a continuity tester or multi-tester. If a multi-tester, turn dial to one of the Ohm settings. Place one probe into one of the terminals on the end of the hose. This will be referred to as T1. Touch the other probe to each of the terminals/connections on the other end of the hose. These will be T3 and T4. One of them should read zero, the other should read infinity. Repeat this with the other terminal, which will be T2.

Drop a marble in one end of hose and let it roll through. If it doesn’t roll through, the hose is clogged and needs to be cleared. Plug hose into the exhaust port of the vacuum, place other end in the in port. Turn vacuum on. This provides a blowing and sucking action which should clear the hose.
Detach hose from power nozzle (PN). Drop a marble into the wand end of PN. If it rolls through, it’s clear. If not, there’s probably a clog behind the brush where the intake opening is. You may be able to reach this through wand end with needle nose pliers, or either end with a knitting/crochet needle or a bent coat hanger.

If none of these “fixes” provide the answer to the problem, it should be taken to the nearest Aerus Electrolux store for diagnosis. Repairs or checks involving disassembly of the vacuum should always be done by an authorized Aerus Electrolux service technician.

The store nearest you can be found by following the instructions at the below listed link:
http://www.aerushome.com/storelocator/

My electrolux oxygen cannister has the “bag change” light on when there is a new bag. The light stays on when the suction power is high (to pick up small particles) and it won’t pick up, but the ight goes off when the suction power is low (to pick up big objects). I changed the hepa filter, cleaned the motor filter and changed bags, but all that didn’t help.
ANSWER : You may have a clog in the hose, and/or the inlet by the brush roll. A clog will turn on that light as well as a full bag.

Hoover SteamVac Model F6056-900 SteamVac/SpinScrub. Indicator light and high pitch suction noise indicates that dirty water tank is full. However, water level indicator (yellow bobbing plastic thing) is at the bottom of the tank and there is no water in the tank. Have check all the hoses for clogs, none found. Checked water port from motor area to receptacle tank for clogs, none found. Fixed broken hose to upholstery wand with duck tape, (wire not broken, just cracked plastic hose). The onl
ANSWER : There are 2 filters, make sure they are clean, one is on the tank lid, the other is from the bottom, it is red, pull it out and clean it. If yours has a foam filter on the tank lid covering the yellow ball, make sure there is at least a 1/4 in. gap from the top. Also make sure that the lid in on and secured tightly.

When I flip the switch on my sebo x1 upright, a red light comes to the brush and bag icons. However, I cleaned out the hose and checked to make sure there is no obstruction from the brush to the hose also, or from the hose to the bag. It is clear that juice is coming to the vacuum, but there is no sign of life except the two red lights.
ANSWER : Thanks for contacting fixya. You should pull out the bag and reset the machine. You should take all the user replaceable items. And turn it on. You will get lot of errors. Then turn the machine off. Put back all the accessories and the bag. Turn you machine on. This will solve your problem.

I have a new Kenmore magic bued and I am about to change bags for the first time. Trying to do this the clip that is supposed to hod the bag close to the whole keeps coming off when I replace it and close the lid, turn on the vac the sucction is very low and it keeps showing the bag is full which is not true / what is going wrong here ?

Thanks so much for supporting,

Beba

ANSWER : Sorry to hear that you are having problems with you Kenmore Magic Blue.

There is a so-called “bag full indicator”, which will only turn red if it got some major blockage. This is the reason why there is no power suction.

The “full bag sensor is just a spring mechanism that springs closed when there is a blockage. Remove the bag and look for clogs. When using it, check the bag and change it when full, not go by the “bag full indicator.”

Good luck, I hope this helps.

Bag was full, changed it, the unit now turns off
ANSWER : Try dialing the control valve to the mid way position. If the unit still shuts down with the bag full light on you have a damaged control valve under the dial on the top of the vac.
This valve failure is common in this model and can only be repaired by someone with original AERUS Electrolux repair parts, generally at an AERUS repair shop.

No suction Hello – any help with this would be much appreciated!

I just changed the bag and filters. The machine runs, seems normal, but there is no suction. There is no blockage of the hose, as indicated by the fact that that little viewer window above where the hose connects to the unit is not showing the red portion that it shows when there is something blocking the hose (god, this is hard to describe!).

If I disconnect the hose and put my hand over the hole, I feel some suction. But

ANSWER : Well, it actually sounds like there is a blockage. Try removing your hose and dropping something through it, like a quqrter. If it comes through, no clog. If it is clogged, I believe that machine has a blower on the upper part of the cleaner (maybe in the bag compartment towards the top. You can take out the filter holder and plug the hose in there and run the unit . Does the blockage come out? If not, Try shaking the hose, or you can put a stiff wire in it to try to free it. Do not run water through it. If there is no blockage at all, then you will probably need to take it to a service center. But I am pretty confident that we are looking at a clog situation. Let me know if this fixesya! Thanks, Rene (vacuum Doctor)