replacing the hose with a new one and that didn’t help.
Electrolux Eureka Easy Clean 2 in 1 Stick and Handheld Vacuum Model 108A 1 ea

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

A few things you can check to try and solve:

Turn off the vacuum cleaner – then check if the nozzle, tube, hose or filters are blocked and/or dirty. Let the product cool down for a minimum of 2 hours on the charging stand before starting it again (stick vacuum cleaners only)

Loose connections will cause your vacuum cleaner to lose suction. Make sure that the dust container, the hose, the tube and the brush are all attached properly. If the problem continues, your vacuum cleaner might have a technical problem. If you suspect this to be the case, contact an authorised service agent.
Why Does My Electrolux Vacuum Head Turn On and Off? Typically, an intermittent on/off issue has to do with a connection between the vacuum head and the hose handle.
Check for a plugged hose:

Hoses can get clogged with hair, dust bunnies, string, or anything else that can`t pass through the other end of the hose. Airways inside the machine should be looked at as well. Wherever there is an air passage, check it. If it`s clear, move onto the next item.

If your roller is not spinning, the first step is to remove the roller and free any debris. Refer to your model`s user manual on how to remove the roller from your vacuum head. Debris can also be left on the vacuum head it is important to also clean this area including the sides where the roller brush connects.
All vacuum cleaners operate based on air flowing from the opening at the cleaning head or tool, through the vacuum cleaner and the bag and/or filter system and then out the exhaust port. This airflow is created by the vacuum motor, which also may be referred to as the suction motor.
Vacuum cleaners are fairly simple machines. They need power to be transmitted to the vacuum to create a suction force that lifts debris. So, the usual areas that cause suction loss include the wrong height setting, stuck rollers, a faulty gasket, a broken vacuum belt, a filled bag, or a clogged hose.
A damaged vacuum hose, clogged motor air filter or bad suction motor can cause the vacuum cleaner to shut off during use. A tripped overload on the vacuum suction motor can shut off the vacuum cleaner during use. If your vacuum has a reset button, push it; if the vacuum seems hot, let it cool off first.
Our customers love their Electrolux vacuum cleaners, and it`s easy to see why. Electrolux vacuum cleaners are known for their superior quality, suction power, and durability. Some customers noted that their old Electrolux vacuums lasted them over 30 years– that`s no small feat!
Start the engine and spray

Scope out all the vacuum lines under the hood. Then start the engine and spray each connection with a light stream of water. If a connection sucks in the water, you`ve found your leak. A vacuum leak can cause a rough idle, high rpm, poor gas mileage and even trigger a check-engine light.

If all you hear from the vacuum unit is a click at the when you try to start the vacuum motor from inside the house, then the motor in the unit is dead and has to be replaced. A strong odor from the shellac, which coats the copper coil windings, is an indicator that the motor is about to or has burnt out.
A damaged vacuum hose, clogged motor air filter or bad suction motor can cause the vacuum cleaner to shut off during use. A tripped overload on the vacuum suction motor can shut off the vacuum cleaner during use. If your vacuum has a reset button, push it; if the vacuum seems hot, let it cool off first.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

My Ultralux 2000 vacuum power head does not work on my machine but does work on a different machine. What are the possilbe problems? I tried replacing the hose with a new one and that didn’t help.
ANSWER : It’s probably due to bad wiring connections between the wands, hose and wand, or power nozzle and wand. If it came with the Sidekick, try using it on the end of the hose. If not, simply try using the power nozzle on the end of the hose (no wands). If it works, then the problem is going to be with the cord sections in the wands. Check them good for cracks, breaks, and discoloration at connections. Replace if necessary.

The motor on my Epic 6500 works, the hose is sucking, but the power head isn;t working… I tried the sidestep power head and that one works. Ive opened and replaced the belt and that is fine. The bulb was already burned out and wasn’t replaced so I cant tell if theres power to the head. What else could it be?
ANSWER : Connect the power nozzle directly to the hose and try.
.Check the terminals where the wand connects to the PN. If any are discolored or cracked, that may be the problem.
.Open the PN and check for loose or broken wires and connections. Repair or replace as necessary.
.The reset switch could be broken or worn out. You can check this with a continuity tester or multimeter.
.If none of these solve the problem the vacuum needs to be taken to your local Aerus Electrolux store for diagnosis and repair.
.
.http://www.aerushome.com/storelocator/

Power head attachment works great when plugged into the hose part of the vacuum. The problem is when I attach it to the tube for normal use there is no power. I have checked all the connections and switched the power switch on and off still no power from tube to power head.
Is there anything else I can try? Model Callisto
ANSWER : Try having someone turn the machine on and off while you pull the cord in and out with the cord more angled towards the on/off switch. Sometimes these models have a break in the cord rewind and will not put the power through to the motor.

Keep in mind this is repairable, and if the unit is less than 5 years old it should still be under warranty.

Good luck .

Our Electrolux canister vacuum just stopped working when we were vacuuming the floor. The power does come on when the power head is attached but as soon as the power head is removed the power shuts off. I tried pressing the reset button but that doesn’t help. Is there a solution that I can try at home?
ANSWER : Sound like you problem is in the connection going to the power head you will see a small screw on the power nozzel where it joins to the handle take out the screw and take it a part you will see where one of the bars have been disconnect from the power.

The original belt on my upright Kenmore Progressive broke and I replaced it with the spare that was in the vacuum. The vacuum and spare belt are about 10 years old. Then the spare broke after one vacuuming session and there was a burning smell coming from the vacuum. I ordered new belts and replaced it with the new belt. It seems to be working fine with no smell. I checked the belt after I vacuumed the family room and although it was in tact, the belt was very hot. Is that normal? Should t
ANSWER : The belt heats up due to the friction, as well as being in contact with the shaft of a hot motor. It is normal.

Unbeknownst to me, someone took the bag out of my Kenmore Progressive vacuum and failed to replace it. I have been vacuuming without a bag for months, and today the vacuum stopped sucking. When I opened up the front to replace the bag, tons of dirt and dust came pouring out. I thoroughly cleaned the vacuum, put in a new bag, but still no sucking power. Just dust coming from the rear vents where one of the filters is. Is the vacuum ruined, or is it a simple solution of buying a new filter?
ANSWER : Sounds like you need to buy a new motor. All that grit and dust will ruin a motor and I’m surprised it lasted as long as it did.
.This is where a vacuum that won’t run without a bag would have been nice. (Aerus for one)

Dirt Devil M082475 12 AMP cannister vacuum power-head problem
ANSWER : Theres no fuse, you will need a new hose

My home has a central vacuum system hook-up but no vacuum installed. My friend upgraded his central system and gave me his Eureka Mega Boss central vacuum system and the accessories, including the pow
ANSWER : The power head requires 120 Volts. Some hoses have a receptacle in the handle for the power head plug, and the hose has a cord at the wall inlet end that plugs into a receptacle. Some hoses have a plug at the wall inlet end that plugs into a 120Volt receptacle built into the inlet. The hose plugs into this receptacle when you push the hose into the inlet. The power for this built-in receptacle is wired with line voltage when the system is installed.