The superficial causes for your VAX vacuum shutting off during use can be from blockages along the hose and body of the model. There can also be a blockage caused by a build-up of dust, dirt, hair and debris across the models` brush bar.
Overheating usually occurs because the dust bag has not been emptied, filter has not been cleaned or there is a blockage in the floor tool, wand or bent hand piece. If your vacuum shuts down unexpectedly, make sure you turn the vacuum off and unplug it from the wall socket.
If your vacuum cleaner keeps turning off, this could be due to the following reasons: Blockages – check the hose and head for any obstructions. Filter – always check your filters, if these are clogged this could be causing the vacuum cleaner to work harder and lose suction power.
If there is something that has become caught in the hose in another part of the system, the airflow will be reduced and can cause overheating and a shut down. Clear out hoses, attachments, and brushes of any hair, dirt, and debris. This will allow for restored airflow and should get things going again.
The carpet washer is drawing too much electricity. This is typical when the motor is seeing too much back resistance (meaning bearings or belts need maintenance) or the motor`s windings are slightly damaged (due to abrasion by dust) or some other means.
If your motor is overheating during vacuuming you`ll find that the cleaner will cut out and no longer perform as it should.
Vacuum cleaners are often designed to turn themselves off if they hit a thermal cut-off point. Basically, if the machine is starting to overheat, there is an automatic system in place to prevent damage to your vacuum or other issues. The most common cause of overheating is blockage.
Problems can occur when overused or clogged filters cause the vacuum motor to overheat. This not only shortens the motor life but causes a loss of suction. In some cases, total motor burn out can occur.
Low suction or poor pick-up may be due to a clog in the vacuum cleaner. If you notice a change in the sound of the motor or a reduction in the spinning action, check for clogs. First, remove the Easy Empty dirt tank from the vacuum and discard all dirt and debris.
If your vacuum is fairly new and this is the first time you`re experiencing a problem, repairs are probably the best option. In fact, your vacuum may still be covered under warranty. However, if you`ve had to pay for multiple repairs and you`ve had the appliance for many years, it might be time for a new one.
The average life expectancy of a mid-range vacuum cleaner is about six years. You can fix or replace things like blocked filters, jammed brush rolls, frayed hoses, worn-out stick vac batteries and broken accessories yourself.
Most Dyson vacuums have a built in safety system that stops the machine if it begins to overheat. This usually happens because the filters need washing or your machine is blocked.
On average, you can expect an upright or cylinder vacuum cleaner to last around 7-8 years – although this varies a lot depending on the brand.
Vacuums often cause “nuisance tripping” with AFCI circuit breakers because vacuums produce a small amount of sparking as they run. And because sparks are essentially small electrical arcs, they`ll occasionally trip your AFCI breaker. Other devices that are prone to “nuisance tripping” include: Flat screen TVs.
A damaged vacuum hose, clogged motor air filter or bad suction motor can cause the vacuum cleaner to shut off during use. A tripped overload on the vacuum suction motor can shut off the vacuum cleaner during use. If your vacuum has a reset button, push it; if the vacuum seems hot, let it cool off first.
Vacuum Cleaner: Why doesn`t my vacuum cleaner`s brush roll spin? A broken drive belt, damaged brush roll, jammed brush roll bearings, tripped brush roll motor overload, failed brush roll motor or a wiring failure in the wand or nozzle can prevent the brush roll from spinning.
Relevant Questions and Answers :
the most relevant questions and answers related to your specific issue
My vax hoover performance 2200 keeps overheating and cutting out after only 10 minutes
ANSWER : Mine too.. I got local place to do a deep clean (sic) of all the filters but its made little difference. Hardly does a room before cutting out and then you have to wait an hour for it to cool down. am veryy disapointed
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum
I HAVE A BRAND NEW HOOVER MACH-3 CYCLONIC THAT CUTS OFF EVERY FEW MINUTES. IT IS DRIVING ME CRAZY! IT’S LIKE AFTER 5 MINUTES OF VACUUMING IT HAS TO SIT FOR A LEAST AN HOUR THEN YOU CAN VACUUM FOR ANOTHER 5 MINUTES. HELP!
ANSWER : If it were mine and it was brand new I would bring it back and exchange it. It sounds like the motor is over heating and shutting off automatically. Does not sound good. My advice return it.
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum
My Shark vacuum sweeper will run for 10 minutes and shut off. After it sets for 15 minutes it will run for 10 minutes more.
ANSWER : If it runs on NiCad batteries it probably has programmed batteries which can happen, best solution, get new battery, and use til dead before recharge, every time.
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum
Overheating Hoover My Hoover cyclonic 1800w keeps overheating and turning itself off, not sure if it’s the filter, I’ve cleaned it but it didn’t look very dirty.
ANSWER : Most likely caused by a lack of airflow. Check to see if you have airflow at the end of the hose. If not, Remove all of the hoses and ensure that they are not clogged. If there is airflow through the hose; check the air inlet immediately aft of the brushroll, inside the nozzle. This is a very common place for clogs to form.
.
.Also note: contrary to some manufacturers claims, you can not clean (or wash, for that matter;) a hepa filter. The small particles are too embedded in the filter media to ever get completely removed, and the act of cleaning tends to damage the filters, even if you can’t see the damage. This is why bagless life-spans, on average, are half the length of the life-spans of bagged vacuums.
.
.Good luck,
.
.-R
.
.Also note: contrary to some manufacturers claims, you can not clean (or wash, for that matter;) a hepa filter. The small particles are too embedded in the filter media to ever get completely removed, and the act of cleaning tends to damage the filters, even if you can’t see the damage. This is why bagless life-spans, on average, are half the length of the life-spans of bagged vacuums.
.
.Good luck,
.
.-R
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum
Hetty hoover not working. It was working ok until I opened it up to search the bag for a missing jigsaw piece and I put it all back and I hoovered the mess on the floor, then switched off and switched on and hoover would not work? Is there a cut off button on Hetty hoovers?
ANSWER : Know cut off switch, its just not getting power ? 2 things its ether at the wall plug or in side the unit. I have never found a fuse in side them , so it may be just a lose wire did you try other plugs in the house . good luck DFD
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum
My Dyson DC07 stops working after a few minutes. It works again after a further 10 minutes and then cuts out again. I have cleaned the filter and checked for blockages but is still cutting out. Can anyone help?
ANSWER : Have you tried calling Dyson? I had a problem with my Animal, and their tech department talked me though the fix. Worth trying them first.
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum
HVR 200 keeps cutting off.
ANSWER : Henry has a has a thermal cut off (a thermostat that protects the cleaner in case of motor overheating). When you have no bug inside the hoover will be very cold. .
.Check if the hose is blocked with dust.heck also the microtek filter, eventually replace with one from different henry..If there is no dust, and filter is OK, then replace the thermal cutoff..to get parts and support contact numatic:Contact.
.Check if the hose is blocked with dust.heck also the microtek filter, eventually replace with one from different henry..If there is no dust, and filter is OK, then replace the thermal cutoff..to get parts and support contact numatic:Contact.
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum
Electrolux 2 in 1 Ergorapido stick Vacuum. Motor runs then cuts out after 3 – 4 seconds. Sometimes it will run properly for 10 minutes so batteries are good. Why does it cut our usually?
ANSWER : If the hand held is working correctly (By itself) try pulling up a little bit on the 4 metal connection tabs on the wand. The connection tabs were not making a proper connection on my unit.
Read Full Q/A … : VAX Appliances 2000 Canister Vacuum