Another reason the vacuum is not turning on may be that the circuit breaker may have tripped. Check the breaker on the unit and if it continues to fail it usually means the motor is going bad. Another reason can be the bad signal from the unit to the wall inlet.
If the motor still has some life in it, it will start, but if it is going bad, it will only work for 10-15 minutes or less. If it doesn`t start at all, it is obviously bad. Sometimes slapping the motor or vacuum unit will jar the motor and get it to work again for a few minutes. Intermittent motors should be replaced.
NOTE: The reset button is located on the upper left-hand side of the unit where the low voltage wires connect to the unit. It is most noticeable when popped out after the breaker has been tripped. 3.
Alternatively called the reset switch, the reset button allows devices that utilize it, such as a computer or peripheral to be rebooted. Usually, the button is on the front of the device, next to or near the power button.
If your Roomba® i Series Robot Vacuum is not turning on or is not able to charge, rebooting your robot tends to solve most related issues. To reboot your Roomba: Press and hold the CLEAN button for 20 seconds. After you release the button, the light ring will show a white clockwise swirl while it reboots.
The most common problems found in vacuum cleaners are low suction force, excessive noise, burning smell, vacuum not turn on, and overheating. These issues can be fixed by either cleaning the device or replacing some parts of the device. At times, it is best to seek a professional to fix the cleaner effectively.
The suction power is to be measured at the end of the tube of a complete vacuum cleaner (i.e. with tube, hose and filters – but without nozzle). Some manufacturers show the results from measurements made at the suction of the actual vacuum cleaner.
Problems can occur when overused or clogged filters cause the vacuum motor to overheat. This not only shortens the motor life but causes a loss of suction. In some cases, total motor burn out can occur.
Vacuum System Failures:

Reduces or eliminates effectiveness of the turn coordinator, attitude indicator, and heading indicator. Discovered by a low indication on the vacuum gauge or unusual instrument indicators. When the primary air inlet is blocked, the backup inlet automatically opens due to pressure.

The suction power is to be measured at the end of the tube of a complete vacuum cleaner (i.e. with tube, hose and filters – but without nozzle). Some manufacturers show the results from measurements made at the suction of the actual vacuum cleaner.
– Some vacuums have an in-line thermal fuse (often located between the switch lead and the motor coil). If the fuse is blown it will need to be replaced. – Check your home circuit breaker – it may have tripped. – Some vacuums have a brushroll on/off control.
Central vacuums can be equipped with either an electrical power brush or an air-driven power brush. The air-driven (or turbine) systems are frequently less expensive since they do not require electrical wires for power to be run to each wall inlet.
Some vacuums have an in-line thermal fuse (often located between the switch lead and the motor coil). If the fuse is blown it will need to be replaced. – Check your home circuit breaker – it may have tripped. – Some vacuums have a brushroll on/off control.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

On my kenmore central vac no power unplug unit plug it back green light comes on but try turning vac on green light goes off again .
ANSWER : Please clarify that we are talking about the central vac LED/switch panel panel and plugging it into a 110 V wall receptacle.
If I understand when you unplug from the power source ,then plug back in the green LED comes on, looking normal ? But when you manually activate the switch on the motor housing of the vac itself the vac does not start and the LED goes out, so no green or red LED at that point?
If this is the case , Kenmore CV’s built approx 5 years ago (MADE by EUREKA) and prior had a circuit board with attached cord (as opposed to detachable) which was prone to relay failure. There were several symptoms, most common was that the relay on that switch panel /circuit board would fuse on and the vac would continue to run when the hose was detached from the wall.However some I worked on from that era had exactly the same symptom you describe. If your unit is between 5 and 10 years old and this sounds accurate, you can unscrew this curved side panel relay with one philips screw. Inside on the PCB will be an L shaped black or white 24volt relay, generally rated at 10 amps. The replacement board or relay will be rated at least 24V/ 15 amps or more. If you can isolate your motor and test it separtely with a power cord or meter , the realy/board will be the only control componnet left.
If you have a small tipped soldering IRON, not a gun, you can generally find a replacement relay to rebuild the board for about $6 at an electronics parts store. Otherwise you will need to replace the control board itself, anywhere form $45 to $70 plus service call if you have a tech come out to the house, and the tech will just unscrew , detach wires and replace the board, no repair , approx 15 minutes work. This will likely cost over $100.
Please post back with your results

Central Vac will not turn on.
ANSWER : These problems are nearly exclusively caused by a bad circut board and replacing it is the fix. Bad boards can cause many different effects so its nearly impossible to be sure. The 9v signal wire is not enough to short out an entire unit so it is unlikely the hose. If it is a direct connect system and you are pulling power from the 110 somehow that would cause main unit problems but that is unlikely at best. Sounds like a failed board to me.
.
.Best of Luck

Hooked everything up per directions. I plugged it in to the closest electrical outlet and nothing happened. The lights did not light up, the connected wall control and sensors leds do not light up. It appears the unit doesn’t have power. The electrical outlet socket is fine as everything else I plug into it works fine. I have tried every other electrical outlet available. The unit won’t power on from any outlet, and all of those outlets run other things, like power tools an refrigerators
ANSWER : Dear Davehibshman,

Firstly; dismantle the plug and replace the fuse with the same rating as the one you have just taken out. Replace the plug cover, put the plug into the socket and try again. If this doesnt work, there may be a problem with the internal fuse (if one is fitted). Two choices here, either refer this unit to a qualified service personnel/ the place where you got it from, or do the job yourself (which will save you a whole bunch of cash). In your circumstances, I would take it back to the place you got it and ask them to put the fault right, or replace the unit completely; if it is past its warranty or guarantee time, then get back to me with a make and model number of the unit, and I will give you step-by-step instructions on how to solve this.

Yours sincerely

Oz

I have a Kenmore Elegance Vacuum with Dirt Sensor, Model # 116.30750400C, Serial number M41901532. When vacuuming the carpet the power head will work for 3-6 mins then automatically shut off, power is still there and lights work but the power head motor turns off and the suction stops. I will turn it off and on, check the outlet, flick the on off buttons…nothing. I will turn it off for a couple minutes and it turns back on and runs like normal. I’ve check the bags, filters, cleaned the hos
ANSWER : It is an electrical problem in the handle, if you can or know somebody that has any fix it ability it can be fixed in about ten minutes. Oh, and Sears SUCKS!!

We have the water hooked up at the back of machine. there is a spout for the water to come in and fill the ice tray.but is does not. If we turn the water on it fills up the space under the ice basket. I keep getting red light and then the two smal llight one ice and one water come on. We can hear the motor trying to fill the ice try and then lights come on. Please help me this so I can use this product. It did not come with a manual.
ANSWER : The water inlet valve on the back of unit opens when the ice maker needs water. If the valve doesn’t seal good because of sediment or wear it will continue to drip and when the water reaches the ice maker supply tube it will freeze blocking the fill tube.. You can take the water line off the valve and watch to see if it drips.
With the fill tube blocked with ice the water can drip down the back wall or drip into the ice bin or just stop up. You can use a hairdryer to thaw the tube out.

Hoover S3765 I have a Hoover S3765 (serial # 040600024465) and the unit stops working for no apparent reason. The light on top of the unit goes off when it shuts down, so I don't believe it's a problem between the hose, the tube and the floor unit. Sometimes I have to let it sit for over one hour before it will come back on. I've tried different electrical plugs too. Still won't turn on. Any ideas or suggestions?

Thanks

ANSWER : If you light and nozzle motor both go off at the same time, you might have a bad power cord. Mine had this problem which I could verify by jiggling/twisting the cord near the strain relief on the nozzle. It would go on and off as I did this. The cord is cheap to replace, around $13 for the part shipped. Part number is 59134072.

Electrolux Centralux I have a Electrolux Centralux. When I plug the hose in at one of the wall outlets the motor will not start. If I go to the motor and slap the unit it will start…..then…it will not stop unless I unplug the power cord to the motor. If I plug the power cord back in, the unit will not restart until I slap the motor unit again. The unit has only been used 20 – 30 times. Any suggestions?? Thanks, Bruce
ANSWER : I dont know if you had your unit looked at yet but it sounds like the Power module is going. I repair the machines so I know some of the work.

I own a Sanyo 35s 3.5 Rice cooker that has stopped cooking and heating. Power is going to the unit power light comes on. We have checked to make sure that the unit was turned off before unplugging as per the instuctions. Unit was new in Feb 2010 and well taken care of. Anything we are missing here?