Kenmore 25512/ 25513 Progressive Canister Vacuum\015 My progressive on/off switch does not work, vacuum is constant running on, I have to UN-plug it to turn it off, and when i want it to work, i plug it in, it runs all the time and cannot turn off unless I UN-plug it.\015

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

Check service panel for tripped breakers/blown fuses. If breaker is tripped, reset it. If fuse is blown, replace it. If vacuum cleaner is plugged in, be sure power button is in the off position before resetting breaker/changing fuse.
Check that the vacuum cleaner is plugged into a working power outlet and that fuses and breakers don`t need resetting. An activated thermal cut-out due to a blockage is the next most likely cause of the problem. Check for blockages in the hose and filters, and remove any obstructions that you find.
A damaged vacuum hose, clogged motor air filter or bad suction motor can cause the vacuum cleaner to shut off during use. A tripped overload on the vacuum suction motor can shut off the vacuum cleaner during use. If your vacuum has a reset button, push it; if the vacuum seems hot, let it cool off first.
Looking at the wiring diagram (stuck way on the side) there is a standard fuse ! That hot wire directly from the power cord goes to a fuse. I (carefully) cut off the black shrink wrapping, check the continuity and zip. Checking it twice I twisted off the top connectors.
Check For Clogs or Blocks In The Vacuum

Check the hoses, the filters, and throughout the vacuum, and clean out any blockages or clogs. Vacuums will likely also have a recommended cooldown time to ensure that the vacuum won`t overheat. You will need to wait for that time before you turn the vacuum back on.

This overload reset switch button (part number 8191505) is for vacuums. Overload reset switch button 8191505 resets the overload switch when you push it. Unplug the vacuum before installing this part. Wear work gloves to protect your hands.
If all you hear from the vacuum unit is a click at the when you try to start the vacuum motor from inside the house, then the motor in the unit is dead and has to be replaced. A strong odor from the shellac, which coats the copper coil windings, is an indicator that the motor is about to or has burnt out.
A vacuum cleaner can run continuously for 30 – 60 min each time. The vacuum cleaner has no suction power. For example, a hair cannot be sucked up.
The average life expectancy of a mid-range vacuum cleaner is about six years. You can fix or replace things like blocked filters, jammed brush rolls, frayed hoses, worn-out stick vac batteries and broken accessories yourself.
How long do Kenmore vacuums last? A. It`s suggested that the typical vacuum can last up to an average of eight years. With proper maintenance, a Kenmore vacuum could last that long or longer.
If your vacuum always trips the breaker, you most likely have an actual electrical problem. Signs that indicate your AFCI breaker is tripping due to an electrical problem include: Frayed cords. If your vacuum cords are old, frayed or deteriorating, it could be producing dangerous electrical arcing.
Clog located in the vacuum hose

Turn the unit on and feel the suction at the end of the hose handle. If there is no or low suction, then the clog is in the hose. You can remove the clog by running a long, stiff object through the hose, such as a butter knife, starting at the wall end.

The most common problem with a vacuum cleaner is also the easiest to remedy: clogs in the hose or attachments. Also the electrical cord, motor, switch, fan, brushes, and motor bearings can all need repair or replacement. The drive belt may need replacing; and the attachments, hoses, and filters may need unclogging.
Vacuuming every day, or even a few times a day, is not going to create any long term problems.
A universal motor is typically used as suction motor across vacuum cleaners. The universal motor is a series DC-motor that is specially designed to operate on alternating current (AC) as well as on direct current (DC). Universal motors have high starting torque, operate at high speed, and are lightweight.
Most of the time, a solid red light means there`s something wrong with your vacuum`s main brush roll, meaning the brush isn`t spinning correctly. In many cases, a bogged-down brush roll simply won`t spin at all.
The most common reason for vacuum motors failing is overheating. Most `dry` vacuums have a flow-though motor. These motors use the air they have sucked up the dust with, to cool themselves. When there is a blockage, flow-though motors are unable to cool themselves due to the lack of airflow.
One of the easiest ways to increase vacuum cleaner suction is to empty the dust bag or container. Dust containers need to have enough space for airflow, otherwise, they could get clogged and have less suction power. Regularly check your dust compartment and empty or change it when it`s already 70-80% full.
The BMS doesn`t only consist of the actual battery but also the circuitry and other components; together, they ensure the right range of voltage and current reaches the battery for a duration of time. So, in that respect, you can`t overcharge your handphone or vacuum cleaner.
If your vacuum cleaner keeps turning off, this could be due to the following reasons: Blockages – check the hose and head for any obstructions. Filter – always check your filters, if these are clogged this could be causing the vacuum cleaner to work harder and lose suction power.
If you don`t vacuum your carpet, the dirt will break down carpet fibers and create a breeding ground for dust mites and bacteria. In addition, your home will begin to smell musty from the dirt, mites, and other organisms settling into the fibers.
Bed bugs are pretty nimble to escape through the vacuum hose and still survive inside the vacuum for months even without food!
For example, bedrooms and home offices should be vacuumed weekly. Areas with high traffic, such as the kitchen, living room, and children`s playrooms, should be cleaned at least twice a week.
If there is something that has become caught in the hose in another part of the system, the airflow will be reduced and can cause overheating and a shut down. Clear out hoses, attachments, and brushes of any hair, dirt, and debris. This will allow for restored airflow and should get things going again.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

We have a dyson dc 07 animal the machine was working fine then switched off after returning to the machine minutes later it wouldnt switch on, i removed on off switch cover and used a short piece of wire across the brown wires flicked the wall switch and it worked, aha i thought faulty switch aquired a new one to no avail and now even the short piece of wire trick doesnt work, has the motor died do you think, it wasnt over heating or making strange noises prior to refusing to work
ANSWER : It could be the motor. I’m having to replace the brushes on my DC 05. It appears that you can only get brushes for the YDK motors in the DYSON, not the Panasonic motor. Which might be saying something about the YDK motors. What happens is that the carbon brushes wear down which is normal. However, the contact wire from the brush to its connector is set so that when the brush wears down, the wire is short enough to stop the spring etc from damaging the commutator. The end result is that you get an intermittent operation of the motor before it finally dies.
.I believe all the DYSONs come with the option of both motors and you cannot really tell which motor you have until you take the thing to bits. You also cannot change motors without changing various other parts on the hoover. On my DC 05 the writing on the YDK motor tells you which one it is.
.This website www. tasweb.org ,select the DC 05 option and scroll down tells you how to take the thing to bits. A search on google etc for your DC 07 may give similar results. Best of luck!

Brissel Healthy Home Hepa Vacuum:
On/Off Switch works sporadically. Took handle apart and the switch worked for a while. I am wondering if I need to replace the switch?

Also the Brush Switch is having similar problems.

ANSWER : Might not be the switch there is a connection on the swivel by the base that likes to fail

Hoover Windtunnel On/Off switch will not turn Off…Switch seems to work O.K. when pressed directly but not with handle switch…It will turn on but not off..Cam seems to be intact on switch actuator..How does switch come out? Thanx
ANSWER : Take the handle off, then remove the tool holder, then you can get to the switch. Just has tabs on each side of switch, depress them and push it out. These switches will do this after awhile, replacing them is usually the way to correct the problem.

Vacuum dead I have oreck XLx2 bagged upright – the belt ,plug and cord have been replaced – has been working great – now went to plug it in and it does not work – the light goes on in the on/off switch so power is working but vacuum is dead – any suggestions
ANSWER : If the cord coming from the bottom up to the handle is loose, and is a plug, push it in. If that doesn’t help. then could be a problem with the motor. One other thing to check is inside the handle, maybe a wire came loose.

Central vac our central vac will not work unless the main vac in the garage is switched on manualy…. its sucking fine but i have to switch it off at the main switch in the garage after i have used it normaly i just plug in the hose and vac away and it switches itself off we have just had cable installed with a fisher guy in the walls do you think that would be the problem thanks a lot
ANSWER : It is possible that the low voltage wiring that controls your central vacuum has been damaged during the cable work. You can check to see if the low voltage relay is working by shorting the two terminals together at the unit. Just disconnect the two small (18-22 gauge) wires from the unit and short across the terminals where the wires connect. If the unit comes on, the vacuum is fine, and it is most likely the low voltage control wires that have been damaged. It should be a pretty easy fix, if you can get to where the wires are located. They are probably just pulled apart at a joint. Good Luck!!

I have only had my shark steam mop for about a month and only used it twice. I tried to use it yesterday and it would not work. The green light came on and it worked for maybe ten seconds, then it completely shut off. I tried switching outlets and draining the water but nothing worked. It still doesn’t work today either. What do you think is wrong? Does this product have a warranty?
ANSWER : Yes has warranty call Shark/europro.

Our kenmore progressive model #11634922 was working fine today. And then – it’s not. Plugged in – nothing is working on it. We let it cool down (though it didn’t seem hot). Still nothing – no light, no motor. Tried it in some other plugs that we know are functioning well – and still nothing. Any idea what might be wrong with it? It’s six years old but doesn’t get heavy use.

Thanks so much ~ Susan Golden

ANSWER : Hi, it could be a number of things, cord may be bad as well as a problem with the motor. There also is a fuse that could have blown. If you go to sears.com, click on parts, put in your model number, when the page loads, click on the first link and you will have a parts list, and scroll down there will be a parts break-down picture that you can look at. You can also order parts thru the Sears website.

Haier 65 pt Dehumidifier.

I purchased a new Haier Dehumidifier 2 years ago. I believe this is the third season and it had been working great. Very quite and on humid day’s, I have to empty it every 10-12 hrs. Two day’s ago it just stopped working, no indicator lights. I plugged it into another outlet to be sure with the same result. I believe it is either the bucket switch or main switch. What do you think and where can I get parts. I live in MA.

ANSWER : HI, this unit has a 12 amp 125v glass tube fuse on the control board. Chances are you blew this fuse. This can happen if the unit is starved for air and ices up. you must take the front of this unit off to access the fuse of this control board. .
.You can get the fuse, main switch and bucket switch in any electrical store around you...
.Take care