Bissell 7920 ProHeat Pro-Tech Upright Wet/Dry Vacuum\015 Will not spray solution. Belt is not broken.\015

How to Identify and Fix Common Vacuum Problems ?

Our sources include academic articles, blog posts, and personal essays from experienced Vacuum Technicians :

Make sure the Clean Water Tank is seated correctly on the machine. If it isn`t, turn off and unplug your machine, remove and reseat the tank until it clicks into place. This is also a good time to check for cracks or leaks in the tank. If it`s damaged, a replacement can be ordered on BISSELL.com.
First, check to make sure the clean tank has water and/or the water & formula mixture in the tank. If your tank is empty, this could be the reason your machine is not spraying. You will need to fill your clean tank again. Reseat the tank and ensure it sits snug on the machine.
Check to see if the collection water tank outside the bladder is full. The float will activate to cut off suction. Empty the collection tank and test for suction. If there is still no suction at this time, please visit a BISSELL Authorized Service Center.
A possible cause might be that the tank is not properly seated. To assure the tank is seated properly, pick it up and re-seat is so it sits snugly on the unit. If this doesn`t fix the problem, make sure the tank is assembled properly. To make sure they are both latched properly, pick the tank up by its handle.
Check the suction inlet on the body of the vacuum and clear it of debris if needed. Remove the hose from the base of the machine and remove any debris as needed. If necessary, you may use a broom handle to unclog the hose by pushing through both openings.
Locate the brush reset button on the lower back right of the vacuum. Press the button to reset the brushroll To ensure the brush has been reset, plug the vacuum back into the electrical outlet.
If your vacuum cleaner has lost suction power, it`s time to empty the container. Vacuum cleaners come with various foam or mesh filters. These might get clogged over time if not cleaned or replaced properly. This will cause your vacuum to lose suction.
Unplug and check to see if your clean tank is seated properly. Also, remove the dirty water tank and make sure there are no clogs in the hose below it. Remove the filter and clean both the screen and filter of any build up or debris and empty the tank before replacing it.
Locate the brush reset button on the lower back right of the vacuum. Press the button to reset the brushroll To ensure the brush has been reset, plug the vacuum back into the electrical outlet.

Relevant Questions and Answers :

the most relevant questions and answers related to your specific issue

I’m using (or WAS using) a Eureka ”the boss” model 8803. The belt broke, no biggie, so I replaced it with a Eureka model U belt, the problem is when I put the new belt on and turn on the vaccuum, the belt breaks again. I am also having trouble getting the brush roller to fit right when the belt is in place. I can’t find any sharp edges that would cut the belt,nor can I find where any small bits may have broken. Anyone have a solution for me?
ANSWER : First, make sure you have the right belt, second, i am thinking that you are not lineing the roller up right, it will only fit one way. look at the ends of the roller and the grooves where it slides in, you should be able to see clearly how it goes.

Windtunnel belt I have a new Hoover Windtunnel canister. The belt keeps coming off. It happened a couple weeks ago (several times after putting the belt back on) so I assumed I might need a new belt as it might have dried out at the store. I ordered new belts and today I used it for about an hour and the belt came off again, twice. There doesn’t seem to be anything to hold the belt on the stem as it seems to slip off. I have tried it centered, to the left and to the right….can you help. I am v
ANSWER : I’ve successfully used a compatible belt – Royal 104425001 .It’s still new, but for the time being at least – it works.

Hoover WindTunnel Self-Propelled V Belt
ANSWER : I had this same problem with the V belt on my Hoover Vaccuum..
.There are three (3) basic things that will cause the brush roll not to spin..
.1. When handle is upright, brush roll is OFF..2. When switch is set for HARD surface, brush roll is OFF..3. Broken/worn FLAT belt or V Belt, brush roll will not spin.
.
.I noticed that the brush roll was not spinning when my vacuum was set for CARPET. After removing the cover I noticed that the V belt was loose, I thought the belt was worn so I purchased a correct replacement belt and installed it, but the new belt was also loose and when I turned the large flat belt pulley it did not turn the V belt pulley at the same time..
.I double checked the surface setting and I had the vacuum switch set for carpet, but still when I released the handle out of the upright position the brush roll would still not spin..
.My aggravation finally led me to this posting on FixYa’s website..
.The first thing I did was checked the screw to the left of the V belt as suggested by ejmjr5 and this did nothing to solve the problem or create more tension on the V belt, even when the upright handle was not in the upright position..
.After playing around with the surface setting control switch/nob I notice that when I moved the switch out of the HARD surface setting and over to CARPET, I had thought that the switch was set for CARPET as it visually appeared, but I was not pushing the switch over hard enough to click it into the CARPET setting mode..
.VOILA, the brush roll now spins correctly even though the V belt seams to be too loose for the pulley..
.You really have to force the switch into the CARPET setting. Be sure that you hear the switch/nob click into place..
.Now you can effectively clean up after that hangover of a party!.
.Burp!

The belt is broken on our Hoover Allergen Filtration Model U5018-900 120 v. 60 Hz 12.0 A. Belt 38528040. Where can I get the belt and instructions on how to replace the broken belt?
ANSWER : The owner’s manual can be downloaded here (in red, “Download the Instruction Manual (PDF))
.http://www.hoover.com/product.aspx?model=U5018900&ds=false
.Instructions for replacing the belt are on page 9.
.
.You can order the belt here:
.http://www.hoover.com/shop/searchresults.aspx?itemid=221224
.
.Or use the “Retail Locator” on the first site.. Just type in your zip code, and a store that carries Hoover and products near you will be shown.

Is there any way to repair or replace the belt GUIDE on the inside of the belt compartment of a ’97 Hoover Wind Tunnel (not self-propelled)? It became twisted when a belt broke and now the belt rubs against it and sounds really weird, and I’m sure new belts will continue to break.. This guide is a long piece of molded material (part of the compartent wall) to keep the belt from coming off the pulley. It also had a sort of metal clip on it. It was loose and I took it off because of the way the pa
ANSWER : Honestly you should take it to a vac.shop they can fix any vac.

The original belt on my upright Kenmore Progressive broke and I replaced it with the spare that was in the vacuum. The vacuum and spare belt are about 10 years old. Then the spare broke after one vacuuming session and there was a burning smell coming from the vacuum. I ordered new belts and replaced it with the new belt. It seems to be working fine with no smell. I checked the belt after I vacuumed the family room and although it was in tact, the belt was very hot. Is that normal? Should t
ANSWER : The belt heats up due to the friction, as well as being in contact with the shaft of a hot motor. It is normal.

Hi my proheat bissell 7901 stopped pumping water to the floor, but it pumps water from the hand hose. I read the manual and followed how to check belt and the flat belt on right side of shampooer is fine and I turned on and it turns and so do the brushes at the bottom of the machine. I was reading online and I guess there’s two belts on this machine? where can I find the other belt to see if it needs replacing. I guess it’s a ribbed belt? that is the water pump belt?
ANSWER : Just taken ours apart with the same problem… found it was caused by the 2 halves of the main casing coming apart in the area where the upright pedal release is. I found this to be due to the upper casing having broken in 2 places – the bottom of the screw wells..This means that the water tank cannot exert sufficient pressure on the valve to release the water..Only solution is a new top cover assembly

Will not spray solution. Belt is not broken.
ANSWER : Clean out the line were your solution comes out. It sounds like you have a build up of product solution . Check your products you used . Some cleaning product are very sticky. Best of luck Ed.